Specification
Section 1. General
1.1 Scope
1.2 Definitions
1.3 Design considerations
1.4 Building requirements
1.5 Electrical equipment
Section 2. Lifts with totally enclosed car and
enclosures at each level
2.1 General safety factor
2.2 Lift well enclosure
2.3 Guides and fixings
2.4 Buffers
2.5 Top and bottom clearances and runbys
2.6 Lift car
2.7 Door construction and clearances
2.8 Locking devices and switches for car and landing
entrances
2.9 Speed, loading and car capacity
2.10 Requirements for drive
2.11 Counterweights
Section 3. Lifts with totally enclosed car and
enclosures at the upper levels
3.1 General safety factor
3.2 Lift well enclosure
3.3 Guides and fixings
3.4 Buffers
3.5 Top and bottom clearances and runbys
3.6 Lift car
3.7 Door construction and clearances
3.8 Locking devices and switches for car and landing
entrances
3.9 Speed, loading and car capacity
3.10 Requirements for drive
3.11 Counterweights
Section 4. Lifts with partially enclosed car and
enclosures at each level
4.1 General safety factor
4.2 Lift well enclosure
4.3 Guides and fixings
4.4 Buffers
4.5 Top and bottom clearances and runbys
4.6 Lift car
4.7 Door construction and clearances
4.8 Locking devices and switches for car and landing
entrances
4.9 Speed, loading and car capacity
4.10 Requirements for drive
4.11 Counterweights
Section 5. Lifts with partially enclosed car with no
enclosure at the lowest level
5.1 General safety factor
5.2 Lift well enclosure
5.3 Guides and fixings
5.4 Buffers
5.5 Top and bottom clearances and runbys
5.6 Lift car
5.7 Door construction and clearances
5.8 Locking devices and switches for car and landing
entrances
5.9 Speed, loading and car capacity
5.10 Requirements for drive
5.11 Counterweights
Section 6. Lifts with partially enclosed car and no
enclosures
6.1 Installation
6.2 General safety factor
6.3 Liftway
6.4 Guides and fixings
6.5 Buffers
6.6 Top and bottom clearances and runbys
6.7 Lift car
6.8 Door construction and clearances
6.9 Locking devices and switches for car entrances
6.10 Speed, loading and car capacity
6.11 Requirements for drive
6.12 Counterweights
Section 7. Drive systems
7.1 Rope and chain suspension systems
7.2 Hydraulic systems
Section 8. Testing, inspection and servicing
8.1 Test and examination after installation
8.2 Periodic examination, tests and servicing
Appendices
A Guidance to purchaser
B Recommendations for the provision and use of
remote control devices, specially adapted
switches, and sensors for use lift control
switches
C Example of proforma for certificate required for
test and examination after installation
D Ram design calculations
E In-use periodic examinations, tests and servicing
F Certificate required for periodic examination
G Certificate of acceptance by purchaser/user
Table
1 Key to symbols for ram calculations
Figures
1 Control circuit supply circuit (see 1.5.4.2)
2 Internal floor area v. car capacity
3 Typical example of load plate
4 Example of domestic lift with partially enclosed
car and no enclosures
5 Angle of fleet
6 Typical example of direction label for manual
operation
7 Ram wall thickness
8 Flat base with relieving groove
9 Domed base
10 Flat base with welded flange
11 Examples of single jack arrangements
12 Examples of telescopic jack arrangements without
external guidance
13 Examples of telescopic jack arrangements with
external guidance
Minimum safety rules for the design, construction, installation, operation and maintenance of lifts specifically to be used by disabled persons in private dwellings.
Committee |
MHE/4
|
DevelopmentNote |
SUPERSEDES BS 5900: 1980. Being considered for approval under the UK Consumer Protection Act 1987 likely approval date Feb 1993. BS DRAFT 94/707080 DC REFERS TO A NEW REVISION
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Supersedes |
BS 302-4:1987 | Stranded steel wire ropes Specification for ropes for lifts |
BS 302-2:1987 | Stranded steel wire ropes Specification for ropes for general purposes |
ISO 4196:1984 | Graphical symbols — Use of arrows |
BS 302-1:1987 | Stranded steel wire ropes Specification for general requirements |
BS 3535-2:1990 | Isolating transformers and safety isolating transformers Specification for transformers for reduced system voltage |
BS 3535-1:1990 | Isolating transformers and safety isolating transformers General requirements |
BS 4575-1:1979 | Fluid power transmission and control systems Guide for hydraulic equipment and systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.