BS 5990:1990

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Specification for direct gas-fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirement) (2nd family gases)

Available format(s)

Hardcopy , PDF

Withdrawn date

27-07-2006

Superseded by

BS EN 525:1998

Language(s)

English

Published date

30-03-1990

€231.38
Excluding VAT

Foreword
Committees responsible
Specification
1 Scope
2 Definitions
3 Classification of appliances
3.1 By category
3.2 By flue type
4 General requirements
5 General conditions of test
5.1 Test room
5.2 Preparation of appliance for testing
5.3 Test procedure
6 Design and construction
6.1 All appliances
6.2 Appliances designed for permanent outdoor
       installation
7 Soundness
7.1 General
7.2 Complete assembly
8 Heat input
8.1 Measurement
8.2 Tolerance
8.3 Adjustment
9 Combustion
9.1 Combustion requirements
9.2 Methods of analysis
9.3 Conditions of test
10 Ignition
10.1 Pilot burners and ignition devices
10.2 Ignition performance; burner systems with
       permanent pilots
10.3 Ignition performance; burner system with
       interrupted or intermittent pilots
10.4 Ignition performance; burner systems employing
       direct main flame spark ignition
11 Flame stability
12 External temperatures
12.1 Surface temperatures
12.2 Component temperatures
13 Manual gas valves
14 Automatic controls
14.1 General
14.2 Governors
14.3 Gas strainers
14.4 Safety shut-off valves
14.5 Combustion air, pre-purge and post-purge
14.6 Flame supervision system
14.7 Start-gas flame establishment
14.8 Main flame establishment
14.9 Air-gas ratio control
14.10 Thermostats and control of air temperature
15 Motors and fans
15.1 General
15.2 Fan motor temperature
15.3 Lubrication
15.4 Marking
16 Electricity supply
17 Manufacturer's instructions
17.1 General
17.2 Installation instructions
17.3 Servicing instructions
17.4 User's instructions
18 Facilities for commissioning and testing
19 Identification and marking
19.1 General
19.2 Data plate
19.3 Name badge
19.4 Appliance parts
19.5 Electrical data
19.6 Warning notices
19.7 Lighting instructions
20 Air handling
20.1 Air flow rate
20.2 Air flow adjustment
20.3 Profile plate (where fitted)
20.4 Recirculation air
21 Surface heat dissipation
22 Air delivery volume
23 Weather resistance
Tables
1 Surface temperature rise
2 Application of safety shut-off valves
3 Flame supervision device drop-out times
4 Fan motor windings: permissible temperature rises
Figures
1 Paint scratch test apparatus
2 Test duct for air flow measurement
3 Anti-swirl device
4 Air flow regulating device
5 Connecting bend
6 Arrangement of spray heads and associated piping
       for rain test
7 Details of spray head assembly and construction

Gives detailed requirements for direct gas fired forced convection air heaters having heat inputs up to 2 MW, meant for commercial and industrial applications. Does not cover appliances that are meant for installation in domestic dwellings. Gives safety and performance requirements and methods of test. Coverage includes definitions, heat input, combustion, ignition and manual gas valves. Also includes tables and diagrams.

Committee
GSE/20
DevelopmentNote
Supersedes 83/73385 DC, 86/70629 DC, 89/70195 DC and BS 5990(1981) (09/2005)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 5000-99:1973 Rotating electrical machines of particular types or for particular applications Machines for miscellaneous applications
BS 10:1962 Specification for flanges and bolting for pipes, valves, and fittings
BS 5986:1980 Specification for electrical safety and performance of gas fired space heating appliances with inputs 60 kW to 2 MW
BS 5963:1981 Specification for electrically operated automatic gas shut-off valves
BS 4921:1988 Specification for sherardized coatings on iron or steel
BS 1756-4:1977 Methods for sampling and analysis of flue gases Miscellaneous analyses
BS 3955:1986 Specification for electrical controls for household and similar general purposes
BS 3554-1:1971 Specification for gas governors Independent governors for inlet pressures up to 25 mbar
BS 1224:1970 Specification for electroplated coatings of nickel and chromium
BS 6501-1:1984 Flexible metallic hose assemblies Specification for corrugated hose assemblies
BS 1706:1990 Method for specifying electroplated coatings of zinc and cadmium on iron and steel
BS 1756-2:1971 Methods for the sampling and analysis of flue gases Analysis by the Orsat apparatus
BS 5000-11(1973) : 1973 SPECIFICATION FOR ROTATING ELECTRICAL MACHINES OF PARTICULAR TYPES OR FOR PARTICULAR APPLICATIONS - PART 11: SMALL-POWER ELECTRIC MOTORS AND GENERATORS
BS 6448-1:1987 Gas governors Specification for pressure governors with nominal connection size up to 50 mm for gas appliances with inlet pressure up to and including 200 mbar
BS 1756-1:1971 Methods for the sampling and analysis of flue gases Methods of sampling
BS 1756-3:1971 Methods for the sampling and analysis of flue gases Analysis by the Haldane apparatus
BS 4201:1979 Specification for thermostats for gas-burning appliances
BS 5991:1989 Specification for indirect gas fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirements (2nd family gases)
BS 1042-2.1:1983 Measurement of fluid flow in closed conduits. Velocity area methods Method using Pitot static tubes
BS 1179:1967 Glossary of terms used in the gas industry
BS 4504-2:1974 Circular flanges for pipes, valves and fittings (PN designated) Copper alloy and composite flanges
BS 4504-1:1969 Circular flanges for pipes, valves and fittings (PN designated) Ferrous
BS 3554-2:1972 Specification for gas governors Independent governors for inlet pressures up to 350 mbar