• Shopping Cart
    There are no items in your cart

BS 6069-4.4:1993

Current

Current

The latest, up-to-date edition.

Characterization of air quality. Stationary source emissions Determination of the mass concentration of sulfur dioxide. Performance characteristics of automated measuring methods

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-05-1993

€140.23
Excluding VAT

Committees responsible
National foreword
Method
1. Scope
2. Normative references
3. Definitions
4. Description of the automated measuring systems
5. Numerical values of performance characteristics and
    their applicability
Annexes
A. (normative) Determination of main performance
    characteristics of automated measuring systems
B. (informative) Additional performance characteristics
C. (informative) Bibliography
Tables
1. Main performance characteristics
2. Facilities and measuring ranges
B.1 Additional performance characteristics
Figures
1. Example of the components for the extractive method
2. Example of the components for the non-extractive
    method

Specifies a set of values of performance characteristics applicable to the continuous measurement, by extractive or non-extractive methods of gas concentrations of sulfur dioxide up to 8 mg/m3.

Committee
EH/2
DevelopmentNote
Also numbered as ISO 7935 Supersedes 88/55353 DC (09/2005) Reviewed and confirmed by BSI, December 2006. (11/2006)
DocumentType
Standard
Pages
14
PublisherName
British Standards Institution
Status
Current

This International Standard specifies a complete set of values of performance characteristics for automated measuring systems for the continuous measurement of the mass concentrations of sulfur dioxide in stationary source emissions. NOTE 1 If the performance characteristics of an automated measuring system are listed according to Table 1, this ensures that the automated measuring system is reliable and gives satisfactory continuous results. The set of data listed in Table 1 refers to the performance characteristics of measurement methods, including all steps from sampling to recording and, if necessary, storage of data. This International Standard is applicable to extractive and non-extractive automated sulfur dioxide measuring methods. For both methods it implies the applicability of zero and calibration gas and the availability of comparable samples. The automated measuring system can be calibrated with calibration gases, by applying the manual method described in ISO 7934, or by applying an automated measuring system previously verified according to this International Standard using a different principle of detection. The value of the integral performance (3.7) is determined by using ISO 7934 or an automated measuring system verified according to this International Standard with a different principle of detection. At present, the range over which this specification applies is between 0 g/m3 to 0,1 g/m3 and 0 g/m3 to 8 g/m3 (see Table 2 for details). NOTE 2 Although it is impossible to give precise testing details, the requirements and testing principles are also applicable to non-extractive systems. Table 1 – Main performance characteristics Performance characteristics Numerical value Test methods (see Annex A) Detection limit 2 % A.4.2.1.1 Effect of interfering substances ± 2 %a A.4.2.1.2 Response time ≤ 200 sc A.4.2.1.3 Integral performance (sA) ± 2,5 %ad A.4.2.2 a Related to the upper limit of measurement. b The main interfering substances in the flue gas from combustion plants are CO2, CO, NO, H2O and, in smaller concentrations, NO2 and NH3. If the water vapour is not removed from the flue gas of coal and waste fired incinerators, HCl and HN* may also interfere. In special cases there may be other interfering substances (e.g. cyanide). c Assuming an integration time of 30 min. d See 3.7. * See national foreword for details of textual error. The facilities at which the values of the performance characteristics given in Table 1 have been verified according to this International Standard in the appropriate ranges are listed in Table 2. Table 2 – Facilities and measuring rangesb Facility Measuring range g/m3 of SO2a Furnaces for hard coal 0 – 1 to 0 – 8 Furnaces for hard coal with stack gas desulfuration plant 0 to 0,1b Furnaces for brown coal 0 – 0,1 to 0 – 3,0 Furnaces for heavy fuel oil 0 – 0,1 to 0 – 5,0 Refuse incinerator 0 – 0,4 to 0 – 1,0 Coke oven 0 to 1 Calcar with heavy fuel oil 0 to 5 Sulfuric acid recovery plant 0 to 1 a Related to 101,3 kPa, 273 K and dry gas. b See national foreword for additional information.

ISO 6879:1995 Air quality — Performance characteristics and related concepts for air quality measuring methods
BS 1756-1:1971 Methods for the sampling and analysis of flue gases Methods of sampling
BS 6069-4.1:1990 Characterization of air quality. Stationary source emissions Method for the determination of the mass concentration of sulphur dioxide: hydrogen peroxide/barium perchlorate/Thorin method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.