• BS 6141:1991

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Specification for insulated cables and flexible cords for use in high temperature zones

    Available format(s):  Hardcopy, PDF

    Superseded date:  02-10-2002

    Language(s):  English

    Published date:  31-10-1991

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Specification
    Section one. General
    1 Scope
    2 References
    3 Definitions
    4 Temperature ratings
    5 Voltage designation
    6 Core identification
    7 Marking
    8 Dimensional test methods
    9 Electrical test requirements and methods
    10 Durability of marking
    11 Tests on completed cables and cords
    Section two. Requirements for rubber-insulated cables
                    and flexible cords
    12 Conductors
    13 Insulation
    14 Core identification
    15 Fillers
    16 Braid
    17 Sheath
    18 Marking
    19 Construction and overall dimensions
    Section three. Requirements for PVC-insulated cables
                    and flexible cords
    20 Conductors
    21 Insulation
    22 Core identification
    23 Fillers
    24 Sheath
    25 Marking
    26 Construction and overall dimensions
    Section four. Requirements for cables insulated with
                    varnished glass fibre or a combination
                    of rubber and glass fibre
    27 Conductors
    28 Insulation
    29 Core identification
    30 Marking
    31 Construction and overall dimensions
    32 Mechanical properties of cables
    Section five. Requirements for extruded fluorocarbon-
                    insulated cables
    33 Conductors
    34 Insulation
    35 Core identification
    36 Marking
    37 Construction and overall dimensions
    38 Mechanical properties of insulation
    Appendices
    A Method of test for alkali content of glass fibre
    B Guidance on the use of insulated cables and cords in
        high temperature zones
    Tables
    1 Applied voltage and time of application for voltage
        test on core in water
    2 Mass to be used and diameter of pulleys for flexing
        test
    3 Current for flexing test
    4 110 deg C rubber-insulated, non-sheathed cables,
        300/500 V, single core
    5 180 deg C rubber-insulated, non-sheathed cables,
        300/500 V, single core
    6 180 deg C rubber-insulated, braided cables, 300/500
        V, single core and twisted twin
    7 180 deg C rubber-insulated, non-sheathed cables,
        300/300 V, single core
    8 85 deg C rubber-insulated, 85 deg C RS 3-sheathed
        flexible cords, 300/500 V, circular twin, 3-core and
        4-core
    9 110 deg C rubber-insulated, 110 deg C rubber-
        sheathed flexible cords, 300/500 V, circular twin
        and 3-core
    10 180 deg C rubber-insulated, 85 deg C PVC-sheathed
        flexible cords, 300/500 V, circular twin and 3-core
    11 180 deg C rubber-insulated, 180 deg C rubber-
        sheathed flexible cords, 300/500 V, circular twin
        and 3-core
    12 List of test applicable to the insulated cables and
        cords specified in section two
    13 90 deg C PVC-insulated, non-sheathed cables, 300/500
        V, single core
    14 90 deg C PVC-insulated, 85 deg C PVC-sheathed light
        flexible cords, 300/300 V, parallel twin, circular
        twin and 3-core
    15 90 deg C PVC-insulated, 85 deg C PVC-sheathed
        flexible cords, 300/500 V, circular twin, 3-core and
        4-core
    16 List of tests applicable to the insulated cables and
        cords specified in section three
    17 155 deg C glass fibre insulated cables, 300/300 V,
        single core
    18 185 deg C glass fibre insulated cables, 300/300 V,
        single core, twisted twin and twisted 3-core
    19 185 deg C glass fibre insulated, braided cables,
        300/300 V, circular twin and 3-core
    20 150 deg C rubber-insulated, glass fibre braided
        cables, 300/300 V, single core
    21 List of tests applicable to the insulated cables
        specified in section four
    22 150 deg C extruded fluorocarbon-insulated non-
        sheathed cables, 300/300 V, single core
    23 List of test applicable to the insulated cables
        specified in section five
    24 Conditions for use of insulated cables and cords in
        high temperature zones
    Figures
    1 Positions for first measurement of insulation
        thickness
    2 Position for measurement of sheath thickness
    3 Positions of point of intersection of the cross-
        wires of the measuring microscope
    4 Flexing test apparatus

    Abstract - (Show below) - (Hide below)

    Constructional, dimensional and test requirements for cables and cords for voltages up to 300/500 V with PVC, rubber, glass fibre and fluorocarbon insulation for continuous operation at maximum temperatures between 85°C and 185°C.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/17
    Development Note Supersedes BS 6141(1981), 90/29146 DC and 91/29614 DC. (03/2006)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 4727-2:GRP08(1986) : 1986 GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLE TERMINOLOGY
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective