• There are no items in your cart

BS 6262:1982

Current

Current

The latest, up-to-date edition.

Code of practice for glazing for buildings

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-1982

€348.24
Excluding VAT

Foreword
Cooperating organizations
Code of practice
1. Scope
2. References
3. Definitions
4. Design and performance
4.1 Introduction
4.2 Initial constraints
4.3 Glazing system
4.4 Natural lighting
4.5 Thermal considerations
4.6 Sound
4.7 Text deleted
4.8 Security
4.9 Fire
4.10 Durability
4.11 Wind loading
4.12 Maintenance (including reglazing after occupation)
5. Performance of glass and sealing materials
5.1 Introduction
5.2 Constraints
5.3 Descriptions of materials and systems
5.4 Natural lighting
5.5 Thermal considerations
5.6 Sound
5.7 Text deleted
5.8 Security
5.9 Fire
5.10 Durability
5.11 Strength of glass to withstand uniform loading
5.12 Cleaning and maintenance
6. Performance of plastics glazing sheet materials,
      frames and sealing materials
6.1 Introduction
6.2 Constraints
6.3 Description of materials
6.4 Natural lighting
6.5 Thermal considerations
6.6 Sound
6.7 Text deleted
6.8 Security
6.9 Fire
6.10 Durability
6.11 Strength to withstand uniform loading
6.12 Cleaning and maintenance
7. Dimensional recommendations for glazing with glass
7.1 Width of rebate or groove
7.2 Depth of rebate or groove
7.3 Nibs for H-type structural gaskets
7.4 Setting and location blocks
8. Dimensional recommendations for glazing with
      plastics glazing sheet materials
8.1 Width of rebate or groove
8.2 Depth of rebate or groove
8.3 Edge clearance
8.4 Edge cover
8.5 Nibs for H-type structural gaskets
8.6 Setting and location blocks
8.7 Distance pieces
9. Glazing and fixing techniques for glass
9.1 General
9.2 Rebate preparation
9.3 Glazing into rebates and grooves
9.4 Glazing over a nib with structural gaskets
9.5 Internal glazing
10. Glazing and fixing techniques for plastics
      glazing sheet materials
10.1 General
10.2 Rebate preparation
10.3 Glazing into rebates (without beads)
10.4 Glazing into rebates (with beads)
10.5 Sealants
10.6 Cutting of plastics glazing sheet materials
10.7 Fixing with bolts and screws to non-plastics
      materials
10.8 Fixing large panes
10.9 Fixing small panes
10.10 Internal glazing
11. Handling, storage and care on site
11.1 General
11.2 Safety of site
11.3 Storage and care of glass onsite
11.4 Handling and storage of plastics glazing sheet
      materials on site
12. Large openings with structural glass assemblies
12.1 Glazing of display windows using glass fins
12.2 Suspended glazing with annealed glass
12.3 Toughened glass suspended assemblies
13. Frameless doors and entrances
13.1 Toughened glass
13.2 Frameless plastics doors
14. Mirrors
14.1 Glass mirrors
14.2 Plastics mirrors
15. Information
15.1 Provision of information
15.2 The information stages
15.3 Specification of requirements
15.4 Building site conditions
15.5 Materials and processes
15.6 Building owner's manual
Tables
1. Ground roughness categories
2. Design wind pressures
3. Summary of availability of glass types & processes
4. Summary of usage of glazing materials for various
     glass types
5. Glazing materials
6. Typical solar radiant heat properties for glasses
7. Shading coefficients for a selection of 6 mm
     glasses with various arrangements of louvred blinds
8. Solar optical properties of glass and blinds
     materials considered in table 7
9. Thermal insulation properties of glass, excluding
     frame
10. Sound insulation of glass
10A. Single glass performance
10B. Double glass performance
11. Text deleted
12. Minimum rebate depths
12A. Putty fronting
12B. Bead glazing
13. Minimum edge cover for single glass up to and
     including 6 mm thickness
14. Minimum edge cover for single glass exceeding 6 mm
     thickness
15. Minimum rebate dimensions for flush-edged
     insulating glass units with putty fronting
16. Weight of glass for setting block assessment
17. Thermal transmittances (U-values) of single and
     double plastics glazing sheet materials
18. Mean sound reduction index: single glazing
19. Mean sound reduction index: double glazing, both
     panels same thickness
20. Minimum edge clearance for glass
21. Setting block materials and lengths
22. Summary of external glazing systems
23. Pane size reduction to allow for thermal expansion
Numerous figures

Recommendations for the design, installation and maintenance of vertically glazed glass and plastics glazing sheet materials for buildings. Does not apply to patent glazing, furniture and fittings, barriers and balustrades, greenhouses, bent, profiled and corrugated glass, glass blocks and lens lights, glass and plastics bullions and thermoformed and corrugated plastics sheeting.

Committee
B/520
DevelopmentNote
Supersedes 79/10691 DC and 88/10723 DC (02/2003)
DocumentType
Standard
Pages
94
PublisherName
British Standards Institution
Status
Current
SupersededBy
Supersedes

This code of practice gives recommendations for the design, installation and maintenance of vertically glazed (see 3.40) glass and plastics glazing sheet materials for the external walls and interiors of buildings. The recommendations in this code do not apply to: patent glazing (see BS5516); glazing of furniture and fittings; glazing of barriers and balustrades (see BS6180); glazing of commercial greenhouses (see BS5502); glazing of domestic greenhouses; bent, profiled and corrugated glass; glass blocks; glass lens lights (precast and cast in situ); glass and plastics bullions; thermoformed plastics panels; corrugated plastics sheeting (reinforced and unreinforced). NOTE1 All dimensions given in this code for thickness are nominal. Tolerances on glass thicknesses should be in accordance with BS952‑1. NOTE2 It is not possible to state individual tolerances on all the installation dimensions contained in this code. These dimensions, which are based on considered good practice in the glazing industry and assume skilled workmanship, should be reasonably applied.

Standards Relationship
UNE-EN ISO 11734:1999 Identical

BS 6340-2:1983 Shower units Specification for the installation of shower units
BS PAS 23-1(1999) : 1999 GENERAL PERFORMANCE REQUIREMENTS FOR DOOR ASSEMBLIES - PART 1: SINGLE LEAF, EXTERNAL DOOR ASSEMBLIES TO DWELLINGS
BS 8000-7:1990 Workmanship on building sites Code of practice for glazing
BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
PD 6512-3:1987 Use of elements of structural fire protection with particular reference to the recommendations given in BS 5588 \'Fire precautions in the design and construction of buildings\' Guide to the fire performance of glass
13/30274184 DC : 0 BS 5918 - SOLAR HEATING SYSTEMS FOR DOMESTIC HOT WATER - CODE OF PRACTICE
BS DD171(1987) : 1987 GUIDE TO SPECIFYING PERFORMANCE REQUIREMENTS FOR HINGED OR PIVOTED DOORS (INCLUDING TEST METHODS)
BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
BS 7543:2003 Guide to durability of buildings and building elements, products and components
BS 8529:2010 Composite doorsets. Domestic external doorsets. Specification
BS 6150:1991 Code of practice for painting of buildings
BS 4873:2004 Aluminium alloy windows
BS 6093:1993 Code of practice for design of joints and jointing in building construction
BS 8233:1999 Sound insulation and noise reduction for buildings. Code of practice
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BIP 3043 : 2005 BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE
BS 559:2009 Specification for the design and construction of signs for publicity, decorative and general purposes
BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
BS 544:1969 Specification for linseed oil putty for use in wooden frames
BS PAS 24(2007) : 2007 ENHANCED SECURITY PERFORMANCE REQUIREMENTS FOR DOOR ASSEMBLIES - SINGLE AND DOUBLE LEAF, HINGED EXTERNAL DOOR ASSEMBLIES TO DWELLINGS
BS 7412:2002 Plastics windows made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles. Specification
BS 5588-8:1999 Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people
BS 6510:2005 Steel-framed windows and glazed doors
BS 8213-1:2004 Windows doors and rooflights Design for safety in use and during cleaning of windows, including door-height windows and roof windows. Code of practice
BS 8220-1:2000 Guide for security of buildings against crime Dwellings
BS 559:1998 Specification for design, construction and installation of signs
BS 4787-1:1980 Internal and external wood doorsets, door leaves and frames Specification for dimensional requirements
BS 4255-1:1986 Rubber used in preformed gaskets for weather exclusion from buildings Specification for non-cellular gaskets
BS 8220-2:1995 Guide for security of buildings against crime Offices and shops
BS 6180:1995 Code of practice for barriers in and about buildings
BS 6767-1:1999 Transportable accommodation units Recommendations for design and construction of the basic unit
BS 8213-4:1990 Windows, doors and rooflights Code of practice for the installation of replacement windows and doorsets in dwellings
08/30182649 DC : DRAFT MAY 2008 BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE
13/30241578 DC : 0 BS 8233 - GUIDANCE ON SOUND INSULATION AND NOISE REDUCTION FOR BUILDINGS
BS 8300:2001 Design of buildings and their approaches to meet the needs of disabled people. Code of practice
BS PAS 24-1(1999) : 1999 AMD 16981 ENHANCED SECURITY PERFORMANCE REQUIREMENTS FOR DOOR ASSEMBLIES - PART 1: SINGLE AND DOUBLE LEAF, HINGED EXTERNAL DOOR ASSEMBLIES TO DWELLINGS
04/30087608 DC : DRAFT OCT 2004 BS 6100-7 - BUILDING AND CIVIL ENGINEERING - VOCABULARY - PART 7: CONSTRUCTION PARTS
17/30335834 DC : 0 BS 8300-2 - DESIGN OF AN ACCESSIBLE AND INCLUSIVE BUILT ENVIRONMENT - PART 2: BUILDINGS - CODE OF PRACTICE
BS 5502-21:1990 Buildings and structures for agriculture Code of practice for selection and use of construction materials
I.S. 197-2:1985 ALUMINIUM ALLOY WINDOWS
BS 8200:1985 Code of practice for design of non-loadbearing external vertical enclosures of buildings
06/30151736 DC : DRAFT SEP 2006 BS 8213-4 - WINDOWS, DOORS AND ROOFLIGHTS - PART 4: CODE OF PRACTICE FOR THE SURVEY AND INSTALLATION OF WINDOWS AND EXTERNAL DOORSETS
BS 6180:1982 Code of practice for protective barriers in and about buildings
BS 8214:1990 Code of practice for fire door assemblies with non-metallic leaves
BS 7036-2:1996 Code of practice for safety at powered doors for pedestrian use Straight and curved sliding doors and prismatic and folding doors
04/30100932 DC : DRAFT AUG 2004 BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS
BIP 3044 : 2005 BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE
BS 5655-6:2002 Lifts and service lifts Code of practice for the selection and installation of new lifts
09/30166898 DC : 0 BS 559 - SPECIFICATION FOR THE DESIGN AND CONSTRUCTION OF SIGN INSTALLATIONS
BS 7036-1:1996 Code of practice for safety at powered doors for pedestrian use General
11/30256242 DC : 0 BS PAS 24 - ENHANCED SECURITY PERFORMANCE REQUIREMENTS FOR DOOR SETS AND WINDOWS IN THE UK - EXTERNAL DOOR SETS AND WINDOWS INTENDED TO OFFER A LEVEL OF SECURITY SUITABLE FOR DWELLINGS AND OTHER BUILDINGS EXPOSED TO COMPARABLE RISK
BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
06/30143171 DC : DRAFT SEP 2006 BS 7412 - PLASTICS WINDOWS AND DOORSETS MADE FROM UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) EXTRUDED HOLLOW PROFILES
BS 6767-1:1992 Transportable accommodation units Recommendations for design and construction
BS 6375-2:1987 Performance of windows Specification for operation and strength characteristics
BS 5234-1:1992 Partitions (including matching linings) Code of practice for design and installation
BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction
BS 644:2003 Timber windows. Factory assembled windows of various types. Specification
BS 3632:1995 Specification for residential park homes

BS CP153-3(1972) : 1972 WINDOWS AND ROOFLIGHTS - WINDOWS AND ROOFLIGHTS - SOUND INSULATION
BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 4255-2:1975 Specification for preformed rubber gaskets for weather exclusion from buildings Cellular gaskets
BS DD73(1982) : 1982 BASIC DATA FOR THE DESIGN OF BUILDINGS - DAYLIGHT
BS CP3:CH1-2(1973) : LATEST
BS 6206:1981 Specification for impact performance requirements for flat safety glass and safety plastics for use in buildings
BS 5544:1978 Specification for anti-bandit glazing (glazing resistant to manual attack)
BS CP3:CH3(1972) : AMD 1385 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - SOUND INSULATION AND NOISE REDUCTION
BS 2782-1:Method 120C:1990 Determination of the 1/10 Vicat softening temperature of thermoplasticsMethods of testing plastics. Thermal properties
BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
BS CP153-2(1970) : 1970 WINDOWS AND ROOFLIGHTS - WINDOWS AND ROOFLIGHTS - DURABILITY AND MAINTENANCE
BS 476-6(1989) : 1989 FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 6: METHOD OF TEST FOR FIRE PROPAGATION FOR PRODUCTS
BS DD67(1980) : 1980 BASIC DATA FOR THE DESIGN OF BUILDINGS, SUNLIGHT
BS 952-2:1980 Glass for glazing Terminology for work on glass
BS 5051-2:1979 Security glazing Specification for bullet-resistant glazing for exterior use
BS 5357:1995 Code of practice for installation of security glazing
BS 2523:1966 Specification for lead-based priming paints
BS CP153-4(1972) : LATEST WINDOWS AND ROOFLIGHTS - FIRE HAZARDS ASSOCIATED WITH GLAZING IN BUILDINGS
BS CP3:CH4(1948) : LATEST CODE OF BASIC DATA FOE THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE (HOUSES AND FLATS OF NOT MORE THAN TWO STOREYS)
BS 476-8:1972 Fire tests on building materials and structures Test methods and criteria for the fire resistance of elements of building construction

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.