BS 6312-2.2:1997

Current

Current

The latest, up-to-date edition.

Connectors for analogue telecommunication interfaces Sockets for use with plugs specified in BS 6312-1 - Particular requirements for fixed socket-outlets used in permanent wiring installations

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

24-08-2005

€156.59
Excluding VAT

Committees responsible
Foreword
1 Scope
2 References
3 Definitions
4 Classification of fixed socket-outlets
5 General requirements
6 Testing
7 Construction
8 Components
9 Marking
10 Accessibility of electrical connections
11 Provision for earthing and insulation of accessible
    metal parts
12 Terminals
13 Electrical strength and insulation resistance
14 Mechanical strength
15 Resistance to heat
Annex A (normative) Characteristics of components
List of references

Specifies the requirements and tests necessary to ensure the safety and dimensional interchangeability of fixed socket-outlets connected to telecommunications wiring.

Committee
TCT/301
DevelopmentNote
Supersedes 93/630694 DC and 04/30117670 DC. (09/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

This Section of BS 6312-2 specifies the requirements and tests necessary to ensure the safety and the dimensional interchangeability of fixed socket-outlets, as defined in 3.2, intended for connection to telecommunications wiring.

Such socket-outlets may be classified both by function, i.e. as being either primary (surge protected or unprotected) or secondary, and according to their method of mounting, i.e. as surface, flush and panel mounted socket-outlets.

This Section does not apply to sockets incorporated in apparatus.

Socket-outlets conforming to this standard are intended to be suitable for use under the following conditions of service unless otherwise specified:

  • an ambient temperature in the range −5 °C to +35 °C, the average value over a 24 h period not exceeding 25 °C;
  • a situation not subject to direct radiation from the sun or other source of heat likely to raise temperatures above the limits specified above;
  • an atmosphere not subject to excessive pollution by smoke, chemical fumes, rain, spray, prolonged or high humidity or other abnormal conditions.

NOTE Socket-outlets conforming to this standard may be suitable for use in other conditions subject to agreement between manufacturer and user. Information given in a manufacturer’s catalogue may take the place of such an agreement.

This standard applies in conjunction with BS 6312-2.1 and the requirements are in addition to those in that standard.

Requirements for electromagnetic compatibility are not given as socket-outlets do not in themselves produce extraneous emissions, nor is their functioning affected by external emissions. Therefore no emission or immunity tests are necessary.

BS 6312-2.1:1994 Connectors for analogue telecommunication interfaces. Sockets for use with plugs specified in BS 6312:Part 1 Specification for sockets. General requirements
BS 6234:1987 Specification for polyethylene insulation and sheath of electric cables
BS 1210:1963 Specification for wood screws
BS 4662:1970 Specification for boxes for the enclosure of electrical accessories
BS 6746:1990 Specification for PVC insulation and sheath of electric cables
BS EN 60068-2-1:2007 Environmental testing Tests. Test A. Cold
BS 6312-1:1994 Connectors for analogue telecommunication interfaces Specification for plugs
BS EN 60068-2-78:2013 Environmental testing Tests. Test Cab: Damp heat, steady state
BS EN 123000:1992 Harmonized system of quality assessment for electronic components. Generic specification: printed boards
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
BS EN 60068-2-2:2007 Environmental testing Tests. Test B. Dry heat
BS 6217:1981 Guide to graphical symbols for use on electrical equipment
BS EN 60249-2-5:1994 Specifications Specification No 5. Epoxide woven glass fabric copper-clad laminated sheet of defined flammability (vertical burning test)
BS CECC 30401 023:1979 Harmonized detail specification for fixed metallized polyethylene terephthalate film dielectric d.c. capacitors. Rectangular insulated non-metallic case, rigid radial terminations. Full assessment level

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.