BS 6346:1989

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Specification for PVC-insulated cables for electricity supply

Available format(s)

Hardcopy , PDF

Superseded date

15-09-1997

Superseded by

BS 6346:1997

Language(s)

English

Published date

31-12-1989

€231.38
Excluding VAT

Foreword
Committees responsible
Specification
1. Scope
2. Definitions
3. Voltage designation
4. Conductors
5. Insulation
6. Identification of cores
7. Laying-up
8. Bedding
9. Armour
10. Oversheath
11. Cable marking and end sealing
12. Schedule of tests
13. Test conditions
14. Routine tests
15. Regular sample tests
16. Special sample tests
17. Type tests
Appendices
A. Recommendations for selection and operation of
    PVC-insulated cables
B. Recommendations for installation of PVC-insulated
    cables
C. Information required with enquiry and order
D. Special sample tests
E. Resistance of conductor and armour, and armour
    cross-sectional areas
F. Guide to use
Tables
1. Diameter of armour wire
2. Mass of zinc coating
3. Schedule of tests
4. Routine tests
5. Test voltage on complete cables
6. Minimum insulation resistance values
7. Regular sample tests
8. Temperature correction multiplication factors
9. Special sample tests
10. Type tests
11. Requirements for compatibility of insulation and
    oversheath
12. Single-core 600/1000 V cables with circular stranded
    copper conductors
13. Single-core 600/1000 V cables with circular solid
    aluminium conductors
14. Two-core 600/1000 V cables with copper conductors
15. Two-core 600/1000 V cables with solid aluminium
    conductors
16. Three-core 600/1000 V cables with copper conductors
17. Three-core 600/1000 V cables with solid aluminium
    conductors
18. Four-core 600/1000 V cables with copper conductors
19. Four-core 600/1000 V cables with solid aluminium
    conductors
20. Four-core 600/1000 V cables with reduced neutral
    conductor and with stranded copper conductors
21. single-core 1900/3300 V armoured cables with
    circular stranded copper conductors
22. Single-core 1900/3300 V armoured cables with
    circular solid aluminium conductors
23. Three-core 1900/3300 V armoured cables with
    stranded copper conductors
24. Three-core 1900/3300 V armoured cables with solid
    aluminium conductors
25(a) 600/1000 V auxiliary cables, 1.5 mm squared
       solid copper conductors (class 1)
25(b) 600/1000 V auxiliary cables, 2.5 mm squared
       solid copper conductors (class 1)
26(a) 600/1000 V auxiliary cables, 1.5 mm squared
       circular stranded copper conductors (class 2)
26(b) 600/1000 V auxiliary cables, 2.5 mm squared
       circular stranded copper conductors (class 2)
26(c) 600/1000 V auxiliary cables, 4 mm squared
       circular stranded copper conductors (class 2)
27. Selection of cables for a.c. systems
28. Minimum installation radius
29. Test voltage after installation
30. Maximum resistance of conductor and armour for
     single-core cables having aluminium wire armour
31. Maximum resistance of conductor and armour for
     two-core, three-core and four-core cables having
     steel wire armour
32. Maximum resistance of conductor and armour for
     single-core cables having solid aluminium conductors
     and aluminium strip armour.
33. Maximum resistance of conductor and armour for two-
     core, three-core and four-core cables having solid
     aluminium conductors and aluminium strip armour
34. Maximum resistance of conductor and armour for
     600/1000 V auxiliary cables with copper conductors
35. Gross cross-sectional area of armour wires for
     single-core 600/1000 V cables having aluminium
     wire armour
36. Gross cross-sectional area of armour wires for
     two-core, three-core and four-core 600/1000 V
     cables having steel wire armour
37. Gross cross-sectional area of aluminium strip
     armour for two-core, three-core and four-core
     600/1000 V cables for solid aluminium conductors
38. Gross cross-sectional area of armour for 600/1000 V
     auxiliary cables with copper conductors

Test requirements and dimensions for cables for general (including underground) use for operation at voltages up to and including 1900 V to armour or earth and 3300 V between conductors. Includes wire armoured and aluminium strip armoured cables with a range of PVC-sheathed cables without further protection, and multi-core auxiliary cables.

Committee
GEL/20/17
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 7333:1990 Specification for slewing jib cranes
BS 7375:1996 Code of practice for distribution of electricity on construction and building sites
BS 7797:1998 Specification for industrial duct heaters using metal-sheathed elements
BS 6704:1996 Code of practice for selection, installation and maintenance of intrinsically safe electrical equipment in coal mines
BS 3454:1995 Specification for 1.9/3.3 kV, 300 A bolted flameproof cable couplers and adaptors (including 380/660 V and 640/1100 V, 300 A adaptors) for use in coal mines
BS 3905:1995 Specification for 3.8/6.6 kV, 300 A bolted flameproof cable couplers and adaptors, for use in coal mines.

EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
IEC 60228:2004 Conductors of insulated cables
BS 4727-2:GRP08(1986) : 1986 GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLE TERMINOLOGY

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.