Wideband cabled distribution systems Methods of measurement
Hardcopy , PDF
English
31-07-1984
Section one. General
1.1 Scope
1.2 Definitions, designations and abbreviations
Section two. Methods of measurement applicable to both
television and f.m. sound radio signals
2.1 Mutual isolation between system outlets
2.2 Amplitude/frequency response within a channel
2.3 Single intermodulation product
2.4 Signal levels
2.5 Radiation from components
2.6 Carrier-to-noise ratio
Section three. Methods of measurement applicable to
television signals only
3.1 Chrominance-luminance gain and delay inequalities
3.2 Composite beat
3.3 Two signal cross-modulation
3.4 Hum modulation of carriers
3.5 Differential gain and phase
3.6 Echo rating
Appendices
A. Monitoring and assessment of system radiation
B. General information on non-linear distortion
C. Test carriers, levels and intermodulation products
D. Absorbing clamp and its application to
measurement of radiated power
E. Stop filter
F. Cable connecting adaptors
G. Calibration of modulation depth
Tables
1. Correction factors where the modulation depth used
is other than 100%
2. Residual carrier reduction factors
3. Test signal levels relative to reference level
Figures
1. Arrangement of test equipment for measurement of
mutual isolation between system outlets
2. Arrangement of test equipment for measurement of
frequency response within a channel
3. Interpretation of displays for measurement of
frequency response within a channel
4. Basic arrangement of test equipment for evaluation
of the ratio of signal to intermodulation product
5. Connections to input of system head end
6. Measurement of radiation, general set-up
7. Measurement of radiation, component with several
outputs
8. Measurement of radiation, absorbing clamp method
9. Example of general set-up for measurement of
radiation in the frequency range 30 MHz to 300 MHz
10. Example of radiation measurement set-up (frequency
range 30 NHz to 300 NHz) for measurements on the
input port of an active component
11. Radiation method without measurement cable
12. Radiation method with measurement cable
13. Example of radiation measurement set-up for
frequency range 300 MHz to 1 GHz
14. Arrangement of test equipment for carrier-to-noise
ratio equipment
15. Test signals employed for chrominance/luminance
gain and delay inequality
16. Arrangement of test equipment for measurement of
chrominance/luminance gain and delay inequality
17. Displayed pulses: chrominance low and lagging
18. Displayed pulses: chrominance high and leading
19. Connection of test equipment for measurement of
non-linear distortion by composite beat
20. Weighting curve for 625-line PAL system I, C.W.
interference with no special control
21. Measurement of two signal cross-modulation
22. Hum modulation envelope
23. Connection of equipment for measurement of hum
modulation (d.c. method)
24. Calibrated potential divider
25. Stable variable d.c. source
26. Oscilloscope display
27. Connection of equipment for measurement of hum
modulation (a.c. method)
28. Signal D2 for 625-line systems
29. Arrangements of test equipment for measurement of
differential gain and phase
30. Example of the modified staircase waveform
31. Echo rating graticule
32. Arrangement of test equipment for measurement of
echo rating
33. Example showing products formed when 2fa>fb
34. Examples of products formed when 2fa
36. Example of measurement of interference power
between 30 MHz and 300 MHz
37. Detail of absorbing clamp
38 Example of calibration curve of absorbing clamp
39. Calibration of absorbing clamp between 30 MHz and
300 MHz
40. Stop filter
41. Adaptor for components with screwed clamp terminals
42. Adaptor for components with coaxial terminals
43. Calibration of modulation depth
Methods of measuring performance for downstream and upstream television signals and f.m. sound radio.
Committee |
EPL/100
|
DevelopmentNote |
Supersedes 83/23518 DC (09/2005) Reviewed and confirmed by BSI, November 2011. (10/2011)
|
DocumentType |
Standard
|
Pages |
58
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Part of BS 6513 describes methods of measuring the performance of wideband cabled distribution systems for downstream and upstream television signals and f.m. sound radio signals.
A method of monitoring and assessing system radiation is described in Appendix A.
NOTE The titles of the publications referred to in this standard are listed on the inside back cover.
BS 6513-6:1987 | Wideband cabled distribution systems Specification for safety requirements |
BS 4727-3:GRP07(1971) : 1971 | GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING & COLOUR TERMS - TERMS PARTICULAR TO TELECOMMUNICATIONS - & ELECTRONICS - RADIOCOMMUNICATION TERMINOLOGY |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.