BS 6850:2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Gas powered ventilatory resuscitators
Hardcopy , PDF
01-11-2007
English
14-06-2002
Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Cleaning, disinfection and sterilization
6 Connectors
7 Operational requirements
8 Physical requirements
9 Performance requirements
10 Storage and operating conditions
11 Gas supply
12 Marking
13 Information to be provided by the manufacturer
Annex A (informative) Recommendations for face masks
Annex B (informative) Recommendations for materials
Annex C (normative) Method of test for patient valve
function after contamination with vomitus
Annex D (normative) Method of test for tidal volume
Annex E (normative) Method of test for pressure limitation
Annex F (normative) Method of test for delivered oxygen
concentration
Annex G (normative) Method of test for resistance to
spontaneous breathing
Annex H (normative) Method of test for apparatus deadspace
(backward leak)
Annex I (normative) Method of test for flow through patient
demand valves
Annex J (normative) Method of test for storage and operating
conditions
Annex K (informative) Construction and testing of test lungs
Bibliography
Applies to resuscitators intended for use by paramedical and medical personnel and also for emergency use by personnel with very limited training.
Committee |
CH/121/1
|
DevelopmentNote |
Supersedes BS 6850(1987) and 01/562314 DC (06/2002) This standard will be withdrawn on 01/11/2007. (10/2007)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
BS EN ISO 10651-4:2002 | Lung ventilators Particular requirements for operator-powered resuscitators |
BS 5682:1998 | Specification for probes (quick connectors) for use with medical gas pipeline systems |
BS 1752:1983 | Specification for laboratory sintered or fritted filters including porosity grading |
BS EN 285:2015 | Sterilization. Steam sterilizers. Large sterilizers |