BS 6955-1:1994

Current

Current

The latest, up-to-date edition.

Calibration of vibration and shock pick-ups Methods for primary vibration calibration by laser interferometry

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-03-1994

€165.94
Excluding VAT

Committees responsible
National foreword
Methods
1 Scope
2 Apparatus
3 Ambient conditions
4 Preferred amplitudes and frequencies
5 Method 1
6 Method 2
Annexes
A (normative) Calculation of uncertainty
B (normative) Formulae for the calculation of
     acceleration
Tables
1 Displacement amplitudes for minimum points
B.1 Values for Jn for zero points of the Bessel
     function
Figures
1 Measuring system for the fringe-counting method
     (Method 1)
2 Measuring system for the minimum-point method
     (Method 2)

Lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of rectilinear accelerometers using laser interferometry for dynamic displacement measurements. Coverage includes apparatus and ambient conditions.

Committee
GME/21
DevelopmentNote
Also numbered as ISO 5347-1 Supersedes 87/72304 DC (09/2005)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current

ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups.

This part of ISO 5347 lays down detailed specifications for the instrumentation and procedure to be used for primary calibration of rectilinear accelerometers using laser interferometry for dynamic displacement measurements.

It is applicable for a frequency range from20 Hz to 5 000 Hz and a dynamic range from10 m/s2 to 1 000 m/s2 (frequency-dependent).

The limits of uncertainty applicable are as follows:

  • ± 0,5 % of reading at reference
  • frequency (160 Hz or 80 Hz) and reference
  • amplitude (100 m/s2 or 10 m/s2) and reference
  • amplifier gain setting;
  • ± 1 % of reading for frequencies ≥ 1 000 Hz;
  • ± 2 % of reading for frequencies > 1 000 Hz.

BS 6955-2:1994 Calibration of vibration and shock pick-ups Methods for primary shock calibration by light cutting
BS 6955-6:1994 Calibration of vibration and shock pick-ups Method for primary vibration calibration at low frequencies
BS 6955-10:1994 Calibration of vibration and shock pick-ups Method for primary calibration by high impact shocks

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.