BS 7083:1989
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Recommendations for the accommodation and operating environment of computer equipment
Hardcopy , PDF
15-12-1996
English
30-06-1989
Foreword
Committees responsible
Recommendations
1. Scope
2. Siting and construction of computer room
2.1 Siting
2.2 Floor area and layout of accommodation
2.3 Provision for services
2.4 Height
2.5 Raised floor
2.6 Floor loading
2.7 Suspended ceiling
2.8 Access
3. Operating environment
3.1 Introduction
3.2 Recommended conditions
3.3 Air-conditioning: general
3.4 Air-conditioning: dedicated computer rooms
3.5 Cleanliness
3.6 Noise
3.7 Lighting
3.8 Electromagnetic fields
3.9 Anti-static floor covering
4. Electricity supply
4.1 General requirements
4.2 Mains conditioning equipment
4.3 Conducted interference on data lines
4.4 Protection of power supply
4.5 Other power supplies
4.6 Earthing
4.7 Residual-current devices
5. Safety and security
5.1 General
5.2 Fire
5.3 Emergency-stop button
5.4 Water shortage
5.5 Lighting
5.6 Telephones
5.7 Bombs
5.8 Preservation of programs and data files
5.9 Restricted access
5.10 Staffing levels
5.11 Check list of procedures
Appendix
A. Bibliography
Tables
1. Temperature, relative humidity and dust levels
Figures
1. Components of a dedicated computer room
2. Psychometric chart for typical locations
Recommends accommodation of computer equipment, including advice on: construction and accessibility, operating environment, electric power requirements and operational safety and security. Applies both to large computer installations housed in purpose-built computer rooms and to smaller computer installations that require a less critically controlled environment. Intended for those concerned in planning accommodation for computer equipment, not for equipment manufacturers.
Committee |
ICT/1
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 4783-6:1993 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for optical disk cartridges (ODC) |
BS 4783-7:1993 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for optical data disks (CD-ROM) |
BS 4783-8:1994 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for 4 mm and 8 mm helical scan tape cartridges |
BS 5655-5:1981 | Lifts and service lifts Specification for dimensions of standard electric lift arrangements |
BS 5306-0:1986 | Fire extinguishing installations and equipment on premises Guide for the selection of installed systems and other fire equipment |
BS 4783-1:1988 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for disk packs, storage modules and disk cartridges |
BS 8206-1:1985 | Lighting for buildings Code of practice for artificial lighting |
BS 5655-6:1985 | Lifts and service lifts Code of practice for selection and installation |
BS 4783-2:1988 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for magnetic tape on open spools |
BS 5588-3:1983 | Fire precautions in the design, construction and use of buildings Code of practice for office buildings |
BS 5295-2:1976 | Environmental cleanliness in enclosed spaces Guide to the construction and installation of clean rooms, work stations and clean air devices |
BS 6540-1:1985 | Air filters used in air conditioning and general ventilation Methods of test for atmospheric dust spot efficiency and synthetic dust weight arrestance |
IEC 60364-7-707:1984 | Electrical installations of buildings. Part 7: Requirements for special installations or locations. Section 707: Earthing requirements for the installation of data processing equipment |
BS 5295-1:1976 | Environmental cleanliness in enclosed spaces Specification for controlled environment clean rooms, work stations and clean air devices |
BS 5958-1:1980 | Code of practice for control of undesirable static electricity General considerations |
BS 4783-4:1988 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for magnetic tape cartridges and cassettes |
BS 4783-3:1988 | Storage, transportation and maintenance of media for use in data processing and information storage Recommendations for flexible disk cartridges |
BS 5958-2:1983 | Code of practice for control of undesirable static electricity Recommendations for particular industrial situations |