• BS 7273-1:2000

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems

    Available format(s):  Hardcopy, PDF

    Superseded date:  28-07-2006

    Language(s):  English

    Published date:  15-04-2000

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 System design
    5 Fire detection
    6 Control and indicating equipment
    7 Controls and indication
    8 Power supplies and wiring
    9 Commissioning and handover
    10 Servicing
    Annex A (informative) Example of a simple diagrammatic
                          representation of a typical sequence
                          of actions leading to the release of
                          fire extinguishing medium
    Annex B (informative) Example of a sounder sequence for an
                          extinguishing system (coincidence
                          release in automatic mode)
    Annex C (informative) Example of a sounder sequence for an
                          extinguishing system (manual release
                          in manual mode)
    Figure A.1 - Diagrammatic representation of a typical
                 sequence of actions leading to the release of
                 fire extinguishing medium
    Table 1 - Control equipment indications of system status
    Table 2 - System status indicators at entrances to the
              protected space
    Table B.1 - Example of a sounder sequence for an extinguishing
                system (coincidence release in automatic mode)
    Table C.1 - Example of a sounder sequence for an extinguishing
                system (manual release in manual mode)

    Abstract - (Show below) - (Hide below)

    Provides recommendations for the planning, installation and servicing of electrical equipment for actuating of gaseous total flooding fire extinguishing systems. Describes the interface between the fire detection systems and fire extinguishing systems and also applies to fire protection systems for electronic data processing installations. Applicable only to electrically actuated total flooding gaseous fire extinguishing systems to be used in a temperate climate eg the United Kingdom.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/12/4
    Development Note SUPERSEDES BS 7273-1(1990) (02/2000) Supersedes 96/543309 DC. (12/2002)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
    BS 6266:2002 Code of practice for fire protection for electronic equipment installations

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
    BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
    BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
    BS DD233(1996) : 1996 CODE OF PRACTICE FOR GASEOUS FIRE FIGHTING SYSTEMS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective