• Shopping Cart
    There are no items in your cart

BS 7350:1990

Current

Current

The latest, up-to-date edition.

Specification for double regulating globe valves and flow measurement devices for heating and chilled water systems

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

28-10-1990

€217.36
Excluding VAT

Committees responsible
Foreword
Specification
1. Scope
2. Definitions
3. Types
4. Ranges of nominal sizes
5. Ranges of nominal pressure
6. Pressure/temperature ratings
7. Dimensions and tolerances
8. Design
9. Materials
10. Hydraulic performance
11. Type testing
12. Production testing
13. Marking
14. Preparation for storage
15. Manufacturer's certificate
Appendices
A. Information to be supplied by the purchaser
B. Typical flow measurement device constructions
C. Flow coefficient method of test
Tables
1. Ranges of nominal presure (PN)
2. Pressure/temperature ratings: flanged and threaded
    ends
3. Pressure/temperature ratings: compression ends
4. Face-to-face dimensions of flanged double regulating
    globe valves and flow-measurement devices
5. Hole diameters or slot widths of pressure tapping
    point or adaptor
6. Materials for the manufacture of type 1 flow
    measurement devices
7. Range of system flow rates
8. Flow coefficient (Kv) for double regulating globe
    valves
9. Flow coefficient (kvs) for flow measurement devices
10. Body material designation
Figures
1. Type 1 flow measurement devices
2. Type 2 flow measurement devices
3. Type 3 flow measurement devices
4. Type 4 flow measurement devices
5. Typical test system
6. Test section with test piece fitted
7. Test section without test piece fitted
8. Test section for flow measurement device only

Specifies pressure/temperature rating, dimensions, some aspects of design, materials, performance requirements, testing (both type and production testing), marking, preparation for storage and transportation, and installation and operating instructions of double regulating globe valves and flow measurement devices used for heating and chilled water systems.

Committee
PSE/18/2
DevelopmentNote
Supersedes 89/76940 DC and 91/72747 DC (09/2005) Reviewed and confirmed by BSI, October 2012. (09/2012)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies pressure/temperature ratings, dimensions, some aspects of design, materials, performance requirements, testing (both type and production testing), marking and preparation for storage and transportation of double regulating globe valves and flow measurement devices used for heating and chilled water systems.

This standard covers double regulating globe valves and flow measurement devices in the form of fixed and variable orifice valves and as individual orifice fittings made from steel, cast iron and copper alloys with flanged, threaded and compression ends, or for mounting between flanges, in a range of sizes and nominal pressure designations.

NOTE 1 The information to be supplied by the purchaser at the time of enquiry and/or order is given in Appendix A.

NOTE 2 This standard does not cover methods of installation.

NOTE 3 The titles of the publications referred to in this standard are listed on pages 18 and 19.

BS 3692:1967 Specification for ISO metric precision hexagon bolts, screws and nuts. Metric units
BS 6683:1985 Guide to installation and use of valves
BS 4168:1967 Specification for hexagon socket screws and wrench keys. Metric series
BS 4504-3.1:1989 Circular flanges for pipes, valves and fittings (PN designated). Steel, cast iron and copper alloy flanges Specification for steel flanges
BS 2871-1:1971 Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation
BS 6880-2:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment
BS 4439:1969 Specification for screwed studs for general purposes. Metric series
BS 6880-1:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Fundamental and design considerations
ISO 6708:1995 Pipework components Definition and selection of DN (nominal size)
BS 4190:1967 Specification for ISO metric black hexagon bolts, screws and nuts
BS 1387:1985 Specification for screwed and socketed steel tubes and tubulars and for plain end steel tubes suitable for welding or for screwing to BS 21 pipe threads
BS 5154:1989 Specification for copper alloy globe, globe stop and check, check and gate valves
BS 1042-1:1964 Measurement of fluid flow in pipes. Orifice plates, nozzles and venturi tubes.
BS 864:1953 Capillary and compression tube fittings of copper and copper alloy for use with copper tube complying with BS 659 and BS 1386.
BS 5793-2.3(1984) : 1984 AMD 7818 INDUSTRIAL PROCESS CONTROL VALVES - FLOW CAPACITY - METHODS OF TEST
BS 4504-3.2(1989) : 1989 CIRCULAR FLANGES FOR PIPES, VALVES & FITTINGS (PN DESIGNATED) - STEEL, CAST IRON & COPPER ALLOY FLANGES - SPECIFICATION FOR CAST IRON FLANGES
BS 5152:1974 Specification for cast iron globe and globe stop and check valves for general purposes
BS 3600:1976 Specification for dimensions and masses per unit length of welded and seamless steel pipes and tubes for pressure purposes
BS 4504-3.3:1989 Circular flanges for pipes, valves and fittings (PN designated) Specification for copper alloy and composite flanges
BS 6755-1:1986 Testing of valves Specification for production pressure testing requirements
BS 5418:1979 Specification for marking of general purpose industrial valves
BS 6880-3:1988 Code of practice for low temperature hot water heating systems of output greater than 45 kW Installation, commissioning and maintenance

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.