BS 7415(1991) : 1991 AMD 7674
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SPECIFICATION FOR TIME SWITCHES FOR TARIFF AND LOAD CONTROL
15-05-1993
23-11-2012
Gives requirements for testing newly manufactured indoor time switches with operation reserve that are used to control electrical loads, multi-tariff registers and maximum demand devices at certain periods throughout the year. May employ various techniques for electronic circuits. Does not apply to time switches operated by remote control or synchronized by radio-frequency. Covers normative references, definitions, requirements, tests and test conditions, relationship between ambient air temperature and relative humidity, reference and limiting values of the influence quantities, electromagnet for testing the influence quantities, electromagnet for testing the influence of externally produced magnetic field and acceptance tests. BS AMD 7674 RENUMBERS THIS STANDARD TO BS EN 61038
Committee |
PEL/14
|
DevelopmentNote |
Renumbered and superseded by BS EN 61038. Supersedes 86/20620 DC. (12/2005)
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 61038:1990+AMD1:1996+AMD2:1998 CSV | Identical |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
IEC 60817:1984 | Spring-operated impact-test apparatus and its calibration |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60801-3:1984 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60417C:1977 | Third supplement. |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60801-2:1991 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.