BS 7632:1993
Current
The latest, up-to-date edition.
Internal fuses and internal overpressure disconnectors for capacitors for inductive heat generating plants
Hardcopy , PDF
English
15-03-1993
Committees responsible
National foreword
Section one. General
1 Scope
2 Object
3 Definitions
Section two. Performance requirements
4 General
5 Disconnecting requirements
6 Withstand requirements
Section three. Tests
7 Routine tests
8 Type tests
9 Discharge test
10 Disconnecting test on fuses
11 Disconnecting test on disconnector
Appendices
A Guide for co-ordination of fuse and disconnector
protection
B Test procedures for the disconnecting test on
internal fuses
Specifies requirements and tests together with a guide for the co-ordination of fuse and disconnector protection.
Committee |
W/-
|
DevelopmentNote |
Also numbered as IEC 60594 (10/2005)
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
British Standards Institution
|
Status |
Current
|
1.1 This standard applies to internal fuses used to protect capacitors for inductive heat generating plants operating at frequencies between 40 Hz and 60 Hz, in accordance with IEC Publication 110, Recommendation for Capacitors for Inductive Heat Generating Plants Operating at Frequencies between 40 and 24 000 Hz.
1.2 This standard also applies to internal overpressure disconnectors used to protect self-healing metallized dielectric capacitors.
1.3 This standard does not apply to fuses and disconnectors for which the service conditions, in general, are incompatible with the requirements of the standard, unless otherwise agreed between manufacturer and purchaser.
1.4 Fuses and disconnectors conforming to this standard are designed to isolate faulted capacitor elements or capacitor unit, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses and disconnectors are not a substitute for a switching device such as a circuit-breaker, or the external protection of the capacitor bank, or part thereof.
IEC 60110:1973 | Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.