BS 7647:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specification for radio teleswitches for tariff and load control
Hardcopy , PDF
31-08-2015
English
15-10-1993
Committees responsible
Foreword
Specification
Introduction
1. Scope
2. References
3. Definitions
4. Electrical values
5. Mechanical properties
6. Climatic conditions
7. Electrical properties
8. Signal reception, signal decoding and control of
output switches
9. Electromagnetic compatibility (EMC)
10. Tests and test conditions
Annexes
A. (normative) Signal modulation and data format
B. (normative) Specification for optically isolated
diagnostic data
Tables
1. Dimensions and spacing of fixing holes and
terminals
2. Switch breaking current
3. Temperature range
4. Relative humidity
5. A.C. voltage tests
Figures
1. Dimensions and spacing of terminals
2. The two aerial positions for directional aerials
3. Relationship between ambient air temperature and
relative humidity
4. Message format
5. Switching sequence
6. Electromagnet for testing the influence of
externally produced magnetic fields
A.1 Phasor diagram of carrier modulated by data
A.2 Phase of modulated carrier as a function of time
A.3 Amplitude response of the specified transmitter
or receiver data-shaping filter
A.4 Amplitude response of the combined transmitter and
receiver data-shaping filter
A.5 Spectrum of biphase coded low frequency (LF) radio-
data signal
A.6 Time-function of a single biphase symbol
A.7 Eye pattern at the output of the specified receiver
data-shaping filter
A.8 Structure for LF radio-data blocks
A.9 Arrangement of blocks in a multiblock, relative to
clock-time
A.10 Clock-time blocks (type 0)
B.1 Diagnostic wand
List of references
Specifies requirements and type tests for radio teleswitches used for the remote switching of up to four circuits (such as the control of two tariff circuits and a water and space heating circuit).
Committee |
PEL/13
|
DevelopmentNote |
Supersedes 92/30694 DC (10/2005) Reviewed and confirmed by BSI, January 2010. (12/2009)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
BS 7951:2000 | Electricity meters. Alternating-current single-phase static watt-hour telemeters of accuracy class 1 or 2 |
13/30281948 DC : 0 | BS 7856 - CODE OF PRACTICE FOR SPECIAL DESIGN AND OTHER FEATURES OF ALTERNATING CURRENT WATTHOUR METERS FOR ACTIVE ENERGY (MID ACCURACY CLASSES A AND B) FOR USE IN THE UK |
BS 7856:2013 | Code of practice for special design and other features of alternating current watthour meters for active energy (MID accuracy classes A and B) for use in the UK |
BS 7003:1988 | Specification for spring-operated impact-test apparatus and its calibration |
BS 7400(1991) : 1991 AMD 7672 | SPECIFICATION FOR ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2) |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
BS 6667-3:1985 | Electromagnetic compatibility for industrial-process measurement and control equipment Method of evaluating susceptibility to radiated electromagnetic energy |
BS 7527-3.3(1991) : 1991 AMD 7931 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
BS 142-1.4.1:1990 | Electrical protection relays. Information and requirements for all protection relays. Specification for electrical disturbance tests 1 MHz burst disturbance tests |
BS 6458-2.1:1984 | Fire hazard testing for electrotechnical products. Test methods Glow-wire test |
BS 6667-2:1985 | Electromagnetic compatibility for industrial-process measurement and control equipment. Method of evaluating susceptibility to electrostatic discharge |
PD 6499:1981 | Guide to insulation co-ordination within low-voltage systems including clearances and creepage distances for equipment |