• Shopping Cart
    There are no items in your cart

BS 7769-1.2:1994

Current

Current

The latest, up-to-date edition.

Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses Sheath eddy current loss factors for two circuits in flat formation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-07-1994

€231.38
Excluding VAT

Committees responsible
National foreword
Method
1 Scope
2 Normative references
3 Symbols
4 Description of method
5 Formulae for sheath loss factors for high-resistance
    sheaths in a single circuit, lambda 0
6 Calculation of the coefficients H, N and J
7 Notes on transposition of cables
8 Worked examples of calculation of eddy current
    losses
Tables
1 H coefficients
2 N coefficients
3 J coefficients
4 J coefficients
5 J coefficients
6 J coefficients
7 J coefficients
8 J coefficients
9 J coefficients
10 J coefficients

Should be used for most sizes of aluminium-sheathed cables, but is not required for lead-sheathed cables unless they are unusually large.

Committee
GEL/20/16
DevelopmentNote
Reviewed and confirmed by BSI, October 2005. (09/2005) Also numbered as IEC 60287-1-2 Supersedes 93/202174 DC (10/2005)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

This section of IEC 287-1 provides a method for calculating the eddy current losses in the metallic sheaths of single-core cables arranged as a three-phase double circuit in flat formation. The sheaths are bonded at one point or are cross-bonded so that there are no significant sheath circulating currents. Where metallic sheaths are bonded at both ends there are significant circulating currents which result in a lower current-carrying capacity. A method of calculating circulating current losses for double circuits is under consideration.

The method provides coefficients which are applied as corrections to the loss factors for the sheaths of one isolated three-phase circuit. These corrections are negligible for cables where the parameter m is less than about 0,1 (m = ω/107 Rs), which corresponds to a sheath longitudinal resistance higher than 314 µΩ/m at 50 Hz.

Consequently the method should be used for most sizes of aluminium-sheathed cables, but is not required for lead-sheathed cables unless they are unusually large:

The coefficients are provided in tabular form and have been computed from fundamental formulae for sheath losses, the evaluation of which calls for expertise in computer programming which might not be readily available in general commercial situations. The development of simplified formulae for some of the tabulated coefficients is under consideration.

Losses for cables in a single circuit will be covered in IEC 287-1-1 (under consideration).

BS 7888-2:1998 LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) Methods of test
BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

IEC 60287-1-1:2006+AMD1:2014 CSV Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.