BS 7965:2000
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
The selection, installation, operation and calibration of diagonal path transit time ultrasonic flowmeters for industrial gas applications
Hardcopy , PDF
31-10-2009
English
15-04-2000
Committees responsible
Foreword
1 Scope
2 Normative references
3 Symbols and abbreviations
4 Selection
5 Installation recommendations
6 Operational consideration
7 Ultrasonic flowmeter certification
Annex A (informative) Uncertainty calculation for
ultrasonic flow meters
Annex B (informative) Performance specification
Annex C (informative) Derivation and correction of flow
measurement errors
Bibliography
Figure 1 - General ray geometry for transit time velocity
measurement
Figure 2 - Intrusive a) and non-intrusive b) transducer
designs
Figure 3 - Variations in path configuration
Figure 4 - Some typical cross-sectional acoustic path
configurations
Figure 5 - Performance specification summary
Figure B.1 - Performance specification for class 1 meters
Figure B.2 - Performance specification for class 2 meters
Figure B.3 - Performance specification for class 3 meters
Figure B.4 - Performance specification for class 4 meters
Figure C.1 - Un-corrected and WME-corrected flow calibration
data plot for 200 mm diameter USM
Table 1 - USM Classification
Table 2 - Installation criteria
Table 3 - Internal diameter tolerances
Table 4 - Uncertainty tolerances for beam path lengths
Table 5 - Nominal test flow rates
Table C.1 - Flow calibration data table for 200 mm diameter
USM
Table C.2 - Flow weighted mean error calculation summary for
200 mm diameter USM
Table C.3 - "WME-corrected" flow calibration data summary
for a 200 mm diameter USM
Supplies a guide to the installation, selection, calibration and operation of diagonal path transit time gas ultrasonic flowmeters (USMs) for industrial gas applications. Only applies to devices where the entire gas stream flows through the body of the USM and the transducers are in contact with the fluid (wetted or invasive type). Includes full-bore and insertion type meters employing reflective or direct paths, and covers "dirty gases", i.e, gas that has been contaminated with solids and/or liquids in small quantities. Does not apply to clamp-on/externally mounted meters.
Committee |
CPI/30/5
|
DevelopmentNote |
Supersedes 98/125725 DC (10/2005) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
BS EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full General principles and requirements |
BS EN 50081-1:1992 | Electromagnetic compatibility. Generic emission standard Residential, commercial and light industry |
BS 7834:1995 | Specification for turbine meters used for the measurement of gas flow in closed conduits |
BS EN 50082-2 : 2012 | ELECTROMAGNETIC COMPATIBILITY - GENERIC IMMUNITY STANDARD - INDUSTRIAL ENVIRONMENT |
BS ISO/TR 12765:1998 | Measurement of fluid flow in closed conduits. Methods using transit-time ultrasonic flowmeters |