• Shopping Cart
    There are no items in your cart

BS 8103-4:1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Structural design of low-rise buildings Code of practice for suspended concrete floors for housing

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-09-1995

Superseded date

30-11-2011

Superseded by

BS 8103-1:2011

€263.42
Excluding VAT
Summarise this standard

Committees responsible
Foreword
Code of practice
1. Scope
2. References
3. Definitions
4. General
5. Suspended precast concrete floors
6. Suspended cast in situ concrete floors at ground level
Tables
1. Weights of partitions
2. Weights of floor finishes
3. Design table for suspended in situ concrete floors
    No perpendicular partition load; aspect ratio not greater
    than 1.8
4. Design table for suspended in situ concrete floors
    Perpendicular partition load = 0.75 kN/linear m; aspect
    ratio not greater than 1.8
5. Design table for suspended in situ concrete floors
    Perpendicular partition load = 2.0 kN/linear m; aspect
    ratio not greater than 1.8
6. Design table for suspended in situ concrete floors
    Perpendicular partition load = 3.75 kN/linear m; aspect
    ratio not greater than 1.8
7. Design table for suspended in situ concrete floors
    Perpendicular partition load = 7.0 kN/linear m; aspect
    ratio not greater than 1.8
8. Design table for suspended in situ concrete floors
    No perpendicular partition load; aspect ratio greater than 1.8
9. Design table for suspended in situ concrete floors
    Perpendicular partition load = 0.75 kN/linear m; aspect
    ratio greater than 1.8
10. Design table for suspended in situ concrete floors
    Perpendicular partition load = 2.0 kN/linear m; aspect
    ratio greater than 1.8
11. Design table for suspended in situ concrete floors
    Perpendicular partition load = 3.75 kN/linear m; aspect
    ratio greater than 1.8
12. Design table for suspended in situ concrete floors
    Perpendicular partition load = 7.0 kN/linear m; aspect
    ratio greater than 1.8
13. Design table for suspended in situ concrete garage floors
Figures
1. Definitions
2. Precast concrete beam and block type floor built into the
    wall
3. Generic types of precast floor systems
4. Typical bearing details for precast floors
5. Typical bearing details for suspended cast in situ
    concrete fllors at ground level
6. Example of a completed form D
7. Reinforcement details
8. Tables selection procedure
9. L and T shaped slabs
10. Design example: spans and layout
List of references

Recommendations for not more than four self-contained dwelling units per floor accessible from one staircase, of not more than three storeys above ground.

Committee
B/204
DevelopmentNote
Supersedes 90/12982 DC (10/2005)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

⚠

A newer version of this standard is available.

View Current Edition
€263.42
Excluding VAT