    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Code of practice
    1. Scope
    2. References
    3. Definitions
    4. General
    5. Suspended precast concrete floors
    6. Suspended cast in situ concrete floors at ground level
    Tables
    1. Weights of partitions
    2. Weights of floor finishes
    3. Design table for suspended in situ concrete floors
        No perpendicular partition load; aspect ratio not greater
        than 1.8
    4. Design table for suspended in situ concrete floors
        Perpendicular partition load = 0.75 kN/linear m; aspect
        ratio not greater than 1.8
    5. Design table for suspended in situ concrete floors
        Perpendicular partition load = 2.0 kN/linear m; aspect
        ratio not greater than 1.8
    6. Design table for suspended in situ concrete floors
        Perpendicular partition load = 3.75 kN/linear m; aspect
        ratio not greater than 1.8
    7. Design table for suspended in situ concrete floors
        Perpendicular partition load = 7.0 kN/linear m; aspect
        ratio not greater than 1.8
    8. Design table for suspended in situ concrete floors
        No perpendicular partition load; aspect ratio greater than 1.8
    9. Design table for suspended in situ concrete floors
        Perpendicular partition load = 0.75 kN/linear m; aspect
        ratio greater than 1.8
    10. Design table for suspended in situ concrete floors
        Perpendicular partition load = 2.0 kN/linear m; aspect
        ratio greater than 1.8
    11. Design table for suspended in situ concrete floors
        Perpendicular partition load = 3.75 kN/linear m; aspect
        ratio greater than 1.8
    12. Design table for suspended in situ concrete floors
        Perpendicular partition load = 7.0 kN/linear m; aspect
        ratio greater than 1.8
    13. Design table for suspended in situ concrete garage floors
    Figures
    1. Definitions
    2. Precast concrete beam and block type floor built into the
        wall
    3. Generic types of precast floor systems
    4. Typical bearing details for precast floors
    5. Typical bearing details for suspended cast in situ
        concrete fllors at ground level
    6. Example of a completed form D
    7. Reinforcement details
    8. Tables selection procedure
    9. L and T shaped slabs
    10. Design example: spans and layout
    List of references

    Abstract - (Show below) - (Hide below)

    Recommendations for not more than four self-contained dwelling units per floor accessible from one staircase, of not more than three storeys above ground.

    General Product Information - (Show below) - (Hide below)

    Committee B/204
    Development Note Supersedes 90/12982 DC (10/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 8103-3:1996 Structural design of low-rise buildings Code of practice for timber floors and roofs for housing
    11/30214388 DC : 0 BS 8103-1 - STRUCTURAL DESIGN OF LOW-RISE BUILDINGS - PART 1: CODE OF PRACTICE FOR STABILITY, SITE INVESTIGATION, FOUNDATIONS AND GROUND FLOOR SLABS FOR HOUSING
    S.R. 54:2014 CODE OF PRACTICE FOR THE ENERGY EFFICIENT RETROFIT OF DWELLINGS
    04/30104570 DC : DRAFT APR 2004 BS 8103-2 - STRUCTURAL DESIGN OF LOW RISE BUILDINGS - PART 2: CODE OF PRACTICE FOR MASONRY WALLS FOR HOUSING
    BS 8103-1:1995 Structural design of low-rise buildings Code of practice for stability, site investigation, foundations and ground floor slabs for housing
    BS 8103-2:1996 Structural design of low-rise buildings Code of practice for masonry walls for housing
    11/30171810 DC : DRAFT APR 2011 BS 5250 - CODE OF PRACTICE FOR CONTROL OF CONDENSATION IN BUILDINGS
    BS 8103-2:2005 Structural design of low rise buildings Code of practice for masonry walls for housing
    BS 5250(2011) : 2011 CODE OF PRACTICE FOR CONTROL OF CONDENSATION IN BUILDINGS

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 4449:1988 Specification for carbon steel bars for the reinforcement of concrete
    BS 4483:1985 Specification for steel fabric for the reinforcement of concrete
    BS 8000-2.2:1990 Workmanship on building sites. Code of practice for concrete work Sitework with in situ and precast concrete
    BS 8110-1:1985 Structural use of concrete Code of practice for design and construction
    BS 5328-4:1990 Concrete Specification for the procedures to be used in sampling, testing and assessing compliance of concrete
    BS 5328-3:1990 Concrete Specification for the procedures to be used in producing and transporting concrete
    BS 6399-1:1984 Loading for buildings Code of practice for dead and imposed loads
    BS 5750-1:1987 Quality systems Specification for design/development, production, installation and servicing
    BS 8103-1:1995 Structural design of low-rise buildings Code of practice for stability, site investigation, foundations and ground floor slabs for housing
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective