BS DD83(1983) : 1983
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ASSESSMENT OF THE COMPOSITION OF FRESH CONCRETE
Hardcopy , PDF
15-10-1997
English
01-01-1983
Foreword
Cooperating organizations
Recommendations
Section one. General
1. Scope
2. Definitions
Section two. Sampling
3. Sampling and sample reduction
Section three. Analysis methods
4. General
5. Buoyancy (BS 1881) method
6. Chemical (GLC) method
7. Constant volume (RAM) method
8. Physical separation (Laing) method
9. Pressure filter (Sandberg) method
10. Water content
11. Report of sample and test data
Section four. Assessment of the accuracy and precision
of the analysis methods
12. General
13. Procedure A: laboratory assessment of accuracy and
repeatability
14. Procedure B: precision of sampling, sample reduction
and testing
15. Procedure C: accuracy and precision of calibrations
16. Procedure D: assessment of precision of sample
reduction and testing from routine tests
Section five. Procedure for assessing compliance
17. General
18. Considerations affecting compliance
19. Assessment of compliance
Appendix
A. Purchaser's risks
Tables
1. Sample and test sample masses
2. Concentrations of cement solutions for flame photo-
meter calibrations
3. Procedures for assessing bias components
4. Procedures for assessing precision components
5. Calculation of bias and repeatability in procedure A
6. Calculation of repeatability and sampling standard
deviation in procedure B
7. Calculation of bias and calibration standard
deviation in procedure C
8. Calculation of repeatability and standard deviation
of sample reduction and testing. Procedure D
9. Summary of bias values for insertion in the
compliance equation
10. Summary of standard deviation values for insertion
in the compliance equation
11. Purchaser's risks and corresponding normal
probability distribution constants
12. Purchaser's risks when the assumed values in tables
9 and 10 (method A) are appropriate
Figures
1. Apparatus for buoyancy methods
2. General assembly diagram including sampling tower
3. Suitable dimensions for a siphon can
4. Typical cement calibration curve
5. Aggregate calibration line
6. Rapid analysis machine (RAM): general assembly
diagram
7. Calibration line
8. General assembly diagram
9. Splitter unit
10. Aggregate calibration lines
Describes the assessment of the composition of fresh concrete. Gives procedures to be used for sampling and sample reduction, five methods of analysing fresh concrete, one solely for the determination of the water content by drying, methods for the assessment of the accuracy and precision of the five methods of analysis, procedures by which the test results can be used for compliance purposes, and the form of reports to be used.
Committee |
CAB/4
|
DevelopmentNote |
REPLACES BS 1881:PART 2:1970.
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
PD 6534:1993 | Guide to the use in the UK of DD ENV 206:1992. Concrete. Performance, production, placing and compliance criteria |
BS 1881-101:1983 | Testing concrete Method of sampling fresh concrete on site |
BS 4550-1:1978 | Methods of testing cement. Sampling |
BS 4550-3.2(1978) : 1978 | METHODS OF TESTING CEMENT - PHYSICAL TESTS - DENSITY TEST |
BS 1881-107:1983 | Testing concrete Method for determination of density of compacted fresh concrete |
BS 812-1:1975 | Testing aggregates Methods for determination of particle size and shape |
BS 812-2:1975 | Testing aggregates Methods for determination of physical properties |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.