BS EN 1060-3 : 1997
Current
The latest, up-to-date edition.
NON-INVASIVE SPHYGMOMANOMETERS - PART 3: SUPPLEMENTARY REQUIREMENTS FOR ELECTRO-MECHANICAL BLOOD PRESSURE MEASURING SYSTEMS
Hardcopy , PDF
English
01-01-1997
Foreword
1 Scope
2 Normative references
3 Definitions
4 Cuff
5 Display
6 Units
7 Requirements
8 Test methods
9 Information supplied by the manufacturer
Annex A (informative) - Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 93/42/EEC on medical devices
Describes performance, efficiency and safety requirements for electro-mechanical blood pressure measuring systems that, by means of an inflatable cuff are used for non-invasive measurements of arterial blood pressure at the upper arm, the wrist and the thigh.
| Committee |
CH/205/10
|
| DevelopmentNote |
Supersedes 94/506238 DC. (07/2005) 1997 Edition Re-Issued in February 2010 & incorporates AMD 2 2009. To be read in conjunction with BS EN 1060-1. Supersedes 09/30192344 DC. (02/2010)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| EN 1060-3:1997+A2:2009 | Identical |
| NS EN 1060-3 : 1997 + A2 2009 | Identical |
| NF EN 1060-3 : 1997 + A2 2010 | Identical |
| NBN EN 1060-3 : 1997 + A2 2010 | Identical |
| DIN EN 1060-3:2010-03 | Identical |
| NEN EN 1060-3 : 1997 + A2 2009 | Identical |
| I.S. EN 1060-3:1997 | Identical |
| UNE-EN 1060-3:1997 | Identical |
| EN 1060-2:1995+A1:2009 | Non-invasive sphygmomanometers - Part 2: Supplementary requirements for mechanical sphygmomanometers |
| EN 1060-1:1995+A2:2009 | Non-invasive sphygmomanometers - Part 1: General requirements |
| IEC 60601-2-30:1999 | Medical electrical equipment - Part 2-30: Particular requirements for the safety, including essential performance, of automatic cycling non-invasive blood pressure monitoring equipment |
| EN 1060-4:2004 | Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers |
| ISO/IEC Guide 99:2007 | International vocabulary of metrology — Basic and general concepts and associated terms (VIM) |
| EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| EN 60601-2-30:2000 | Medical electrical equipment - Part 2-30: Particular requirements for the safety, including essential performance, of automatic cycling non-invasive blood pressure monitoring equipment |
| EN 60601-1-8:2007/A11:2017 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.