Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents
4.1 General
4.2 Nitric acid (HNO[3]), 65% (d = 1.42)
4.2.1 Nitric acid (4.2), diluted 1:1 (V/V) with water
4.2.2 Nitric acid (4.2), diluted to 1% (V/V) with water
4.3 Hydrochloric acid (HCl), 36% (d = 1.19)
4.4 Hydrochloric acid (HCl), 0.3 mol/l solution
4.5 Cadmium - stock solution (Cd) = 1000 mg/l
4.6 Lead - stock solution (Pb) = 1000 mg/l
4.7 Matrix modifiers
4.7.1 Ammonium dihydrogen phosphate (NH[4]H[2]PO[4])
solution, 100.0 g/l
4.7.2 Palladium nitrate (Pd(NO[3])[2]) solution,
21.7 g/l (= 1% Pd)
4.7.3 Magnesium nitrate (Mg(NO[3])[2]) solution,
61.0 g/l (= 1% Mg)
4.8 Gases for atomic absorption spectrometry
5 Apparatus
5.1 General
5.2 General laboratory equipment
5.3 Volumetric flasks, 1000 ml
5.4 Analytical balance, accuracy 0,1 mg
5.5 Micropipettes from 5,0 [mu]l to 20,0 [mu]l with
plastique tips (high density polyethylene/polypropylene
bottles)
5.6 Atomic absorption spectrometer, with graphite tube
furnace, and with background correction or inductively
coupled plasma atomic emission spectrometer with background
correction and radio frequency-generator
6 Preparation of sample
7 Procedure
7.1 General
7.2 Preparation of reference solutions
7.3 Determination of cadmium and lead
7.3.1 General
7.3.2 Calibration curve
7.3.3 Suggested spectrometer settings
7.3.4 Determination of blank value
8 Expression of results
9 Precision
10 Test report
Defines the test method for the determination of cadmium and lead in an aqueous extract.
Committee |
CW/47
|
DevelopmentNote |
Supersedes DD ENV 12498 and 03/309239 DC. (12/2005) Reviewed and confirmed by BSI, July 2010. (06/2010)
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
This European Standard is one in a series of Standards for the determination of heavy metals in an aqueous extract of paper or board intended for contact with food. This European Standard specifies the test method for the determination of cadmium and lead in an aqueous extract. It is applicable to paper and paperboard with extractable metal contents exceeding - 0,1 mg per kg for cadmium; - 0,6 mg per kg for lead. NOTE 1 The above limits of determination are achieved by multiplying the actual limits existing today or proposed in Europe by 0,2. NOTE 2 Metal content levels below those given can be measured by this European Standard if very sensitive equipment is available and if all other laboratory conditions fulfil the requirements for trace element analysis.
Standards | Relationship |
EN 12498:2018 | Identical |
DIN EN 12498:2005-11 | Identical |
I.S. EN 12498:2005 | Identical |
SN EN 12498 : 2005 | Identical |
UNI EN 12498 : 2005 | Identical |
UNE-EN 12498:2006 | Identical |
NEN EN 12498 : 2005 | Identical |
EN 12498:2005 | Identical |
NBN EN 12498 : 2005 | Identical |
NS EN 12498 : 1ED 2005 | Identical |
ONORM EN 12498 : 2005 | Identical |
NF EN 12498 : 2005 | Identical |
EN 645:1993 | Paper and board intended to come into contact with foodstuffs - Preparation of a cold water extract |
EN 647:1993 | Paper and board intended to come into contact with foodstuffs - Preparation of a hot water extract |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.