BS EN 12619:2013
Current
The latest, up-to-date edition.
Stationary source emissions. Determination of the mass concentration of total gaseous organic carbon. Continuous flame ionisation detector method
Hardcopy , PDF
English
31-01-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 The principle of the technique
5 Requirements for apparatus and gases
6 Measurement procedure
Annex A (normative) - Determination of the performance
characteristics of a FID
Annex B (informative) - Basic functionality of an FID
Annex C (informative) - Measurement uncertainty and
associated statistics
Annex D (informative) - Safety measures
Annex E (informative) - Significant technical changes
Bibliography
Describes the requirements for an instrument using flame ionisation detection, together with procedures for its operation.
Committee |
EH/2/1
|
DevelopmentNote |
Supersedes 96/563986 DC. (08/2005) Supersedes BS EN 13526 & 11/30238654 DC. (02/2013)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic substances (expressed as TVOC) in stationary source emissions (e.g. emissions from waste incinerators and solvent using processes, emission measurements according to 2010/75/EU) in the concentration range up to 1000mg/m³.
This European Standard specifies the requirements for an instrument using flame ionisation detection, together with procedures for its operation. The results obtained using this standard are expressed in milligrams per cubic metre (mg/m³) as total carbon (TVOC).
This European Standard is not applicable for permanently installed automated measuring systems (AMS).
Alternative methods to this method may be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.
Standards | Relationship |
NF EN 12619 : 2013 | Identical |
NEN EN 12619 : 2013 | Identical |
I.S. EN 12619:2013 | Identical |
UNI EN 12619 : 2013 | Identical |
SN EN 12619 : 2013 | Identical |
DIN EN 12619:2013-04 | Identical |
EN 12619:2013 | Identical |
UNE-EN 12619:2013 | Identical |
NS EN 12619 : 2013 | Identical |
NBN EN 12619 : 2013 | Identical |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
EN 15267-3:2007 | Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources |
CEN/TS 14793:2005 | Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method |
ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
EN ISO 9169:2006 | Air quality - Definition and determination of performance characteristics of an automatic measuring system (ISO 9169:2006) |
EN 15267-2:2009 | Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process |
EN 14789:2017 | Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism |
EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
EN 14181:2014 | Stationary source emissions - Quality assurance of automated measuring systems |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
EN 14790:2017 | Stationary source emissions - Determination of the water vapour in ducts - Standard reference method |
EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
ISO 9169:2006 | Air quality Definition and determination of performance characteristics of an automatic measuring system |