• BS EN 12831-1:2017

    Current The latest, up-to-date edition.

    Energy performance of buildings. Method for calculation of the design heat load Space heating load, Module M3-3

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  19-07-2017

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviations
    5 Description of the methods
    6 Standard method - Heat load of rooms, building
      entities and buildings
    7 Simplified method for the calculation of the design
      heat load of a heated space (single rooms)
    8 Simplified method for the calculation of the building
      design heat load
    9 Compliance check
    Annex A (normative) - Input data, structure for default values
    Annex B (informative) - Input data, default values
    Annex C (informative) - Detailed consideration of thermal bridges
    Annex D (informative) - Internal temperatures theta[u] of adjacent
            building entities or adjacent unheated spaces within the same
            building
    Annex E (informative) - Equivalent thermal transmittance of building
            elements against ground
    Annex F (informative) - Estimation of heating-up power in intermittently
            heated spaces (6.3.4)
    Annex G (informative) - External air volume flow through large openings
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines methods for the calculation of the design heat load for single rooms, building entities and buildings, where the design heat load is defined as the heat supply (power) needed to maintain the required internal design temperature under design external conditions.

    Scope - (Show below) - (Hide below)

    This European Standard covers methods for the calculation of the design heat load for single rooms, building entities and buildings, where the design heat load is defined as the heat supply (power) needed to maintain the required internal design temperature under design external conditions. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000 -1. NOTE 1 In CEN ISO/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Tables A.1 and B.1. (...)

    General Product Information - (Show below) - (Hide below)

    Committee RHE/24
    Development Note Supersedes 14/30309932 DC & BS EN 12831. 07/2017)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 13789:2017 Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
    ISO 9972:2015 Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method
    ISO 10211:2017 Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations
    EN 15316-3:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 3: Space distribution systems (DHW, heating and cooling), Module M3-6, M4-6, M8-6
    EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
    EN ISO 10456:2007/AC:2009 BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES
    EN 15316-4-2:2017/AC:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2
    CEN ISO/TR 52000-2:2017 Energy performance of buildings - Overarching EPB assessment - Part 2: Explanation and justification of ISO 52000-1 (ISO/TR 52000-2:2017)
    EN 15316-4-4:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-4: Heat generation systems, building-integrated cogeneration systems, Module M8-3-4, M8-8-4, M8-11-4
    ISO 52000-1:2017 Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
    ISO 15927-5:2004 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 5: Data for design heat load for space heating
    EN 15459-1:2017 Energy performance of buildings - Economic evaluation procedure for energy systems in buildings - Part 1: Calculation procedures, Module M1-14
    EN 15316-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 1: General and Energy performance expression, Module M3-1, M3-4, M3-9, M8-1, M8-4
    ISO 10077-2:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames
    EN 15378-3:2017 Energy performance of buildings - Heating and DHW systems in buildings - Part 3: Measured energy performance, Module M3-10, M8-10
    EN 15316-4-3:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-3: Heat generation systems, thermal solar and photovoltaic systems, Module M3-8-3, M8-8-3, M11-8-3
    EN 12524 : 2000 BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES
    EN ISO 10077-2:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017)
    EN ISO 6946:2017 Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12)
    EN ISO 14683:2017 Thermal bridges in building construction - Linear thermal transmittance - Simplified methods and default values (ISO 14683:2017)
    EN ISO 15927-5:2004/A1:2011 Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 5: Data for design heat load for space heating - Amendment 1 (ISO 15927-5:2004/Amd 1:2011)
    EN 15316-2:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 2: Space emission systems (heating and cooling), Module M3-5, M4-5
    EN ISO 10211:2017 Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017)
    EN ISO 52000-1:2017 Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO 52000-1:2017)
    CEN/TR 12831-2:2017 Energy performance of buildings - Method for calculation of the design heat load - Part 2: Explanation and justification of EN 12831-1, Module M3-3
    EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria (ISO 7730:2005)
    ISO 10456:2007 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values
    EN 15316-5:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 5: Space heating and DHW storage systems (not cooling), Module M3-7, M8-7
    ISO 13370:2017 Thermal performance of buildings — Heat transfer via the ground — Calculation methods
    ISO 7730:2005 Ergonomics of the thermal environment — Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
    EN ISO 13370:2017 Thermal performance of buildings - Heat transfer via the ground - Calculation methods (ISO 13370:2017)
    ISO/TR 52000-2:2017 Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1
    EN 15316-4-8:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-8: Space heating generation systems, air heating and overhead radiant heating systems, including stoves (local), Module M3-8-8
    EN ISO 9972:2015 Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method (ISO 9972:2015)
    ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
    ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
    EN 15378-1:2017 Energy performance of buildings - Heating systems and DHW in buildings - Part 1: Inspection of boilers, heating systems and DHW, Module M3-11, M8-11
    EN ISO 13789:2017 Thermal performance of buildings - Transmission and ventilation heat transfer coefficients - Calculation method (ISO 13789:2017)
    EN 15316-4-10:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-10: Wind power generation systems, Module M11-8-7
    EN 15316-4-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1
    ISO 7345:1987 Thermal insulation Physical quantities and definitions
    EN 12831-3:2017 Energy performance of buildings - Method for calculation of the design heat load - Part 3: Domestic hot water systems heat load and characterisation of needs, Module M8-2, M8-3
    EN ISO 10077-1:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02)
    EN 15316-4-5:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-5: District heating and cooling, Module M3-8-5, M4-8-5, M8-8-5, M11-8-5
    ISO 14683:2017 Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective