BS EN 12953-9:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Shell boilers Requirements for limiting devices of the boiler and accessories
Hardcopy , PDF
English
31-08-2007
23-12-2024
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for limiter
4.1 General
4.2 Materials and design
4.3 Electrical equipment
4.4 Fault assessment
4.5 Marking
5 Special requirements for water level limiters
5.1 Components
5.2 Design
5.3 Floating devices
5.4 Level electrode devices
5.5 Examination of functional capability
5.6 Fault detection
6 Special requirements for pressure limiters
6.1 Components
6.2 Additional fault assessment requirements
6.3 Design
6.4 Electrical equipment
6.5 Examination of functional capability
6.6 Fault detection
7 Special requirements for temperature limiters
7.1 Components
7.2 Design
7.3 Electrical equipment
7.4 Examination of functional capability
8 Special requirements for flow limiters
8.1 Components
8.2 Design
8.3 Electrical equipment
8.4 Examination of functional capability
Annex A (informative) Limiting device
Annex B (informative) Example of an examination plan
Annex C (informative) Marking of limiters
Annex D (normative) Immunity against electrical and electromagnetic
influences - Requirements and testing
D.1 General
D.2 Immunity against mains voltage variations
D.3 Immunity against short-time voltage interruptions and
reductions
D.4 Immunity against mains frequency changes
D.5 Immunity against electrostatic discharge (ESD)
D.6 Immunity against fast transient disturbance variables
(burst)
D.7 Immunity against surges
D.8 Immunity against high-frequency electromagnetic fields
D.9 Immunity against conducted disturbances induced by
high frequency fields
D.10 Immunity against power frequency magnetic fields
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements of EU
Directive 97/23/EC
Bibliography
Describes requirements for limiters (or limiting devices) which are incorporated into safety systems for shell boilers as defined in EN 12953-1.
| Committee |
PVE/2
|
| DocumentType |
Standard
|
| Pages |
40
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
This European Standard specifies requirements for limiters (or limiting devices) which are incorporated into safety systems for shell boilers as defined in EN 12953-1.
A limiter (or limiting device) can be either:
a safety accessory as defined in the Pressure Equipment Directive, Article 1, clause 2.1.3, and needs to include the safety logic and final actuator, or
one element of a safety system, for example, a self-monitoring water level sensor used as part of a safety accessory as defined in the Pressure Equipment Directive, Article 1, clause 2.1.3. The overall boiler protection function needs to be provided in association with additional safety logic (where appropriate) and a final actuator.
The design requirements and examination of functional capability for the limiters are covered in this European Standard.
For an explanation of the extent of the limiter (or limiting device) see Figure A.1.
| Standards | Relationship |
| I.S. EN 12953-9:2007 | Identical |
| NS EN 12953-9 : 1ED 2007 | Identical |
| NF EN 12953-9 : 2007 | Identical |
| DIN EN 12953-9:2007-09 | Identical |
| NEN EN 12953-9 : 2007 | Identical |
| EN 12953-9:2007 | Identical |
| NBN EN 12953-9 : 2007 | Identical |