BS EN 13022-2:2006+A1:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Glass in building. Structural sealant glazing Assembly rules
Hardcopy , PDF
30-06-2014
English
31-08-2010
Committee |
B/520
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy |
This European Standard deals with the assembling and bonding of glass elements in a frame, window, door or curtain walling construction, or directly into the building by means of structural bonding of the glass element into or onto framework or directly into the building.
It gives information to the assembler to enable him to organise his work and comply with requirements regarding quality control.
Structural sealant glazing can be incorporated into the façade as follows:
either vertically; or
up to 7° from the horizontal, i.e. 83° from the vertical.
This European Standard only deals with the bonding to glass surfaces, i.e. coated or uncoated, and metallic surfaces, i.e. aluminium (anodized or coated), stainless steel, as considered in clause G.2 of EN 15434.
Standards | Relationship |
EN 13022-2:2006+A1:2010 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.