BS EN 13060:2014+A1:2018

Current

Current

The latest, up-to-date edition.

Small steam sterilizers

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-12-2018

€327.21
Excluding VAT

This European Standard specifies the performance requirements and test methods for small steam
sterilizers and sterilization cycles which are used for medical purposes or for materials that are likely to
come into contact with blood or body fluids.

Committee
CH/198
DocumentType
Amendment
Pages
86
ProductNote
This standard also refer to prEN ISO 11140-6,TS 11139:2006, IEC GUIDE 51:1999, 93/42/EEC, COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993, 97/23/EC, Directive 97/23/EC of the European Parliament and of the Council of 29 May 1997
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard specifies the performance requirements and test methods for small steam sterilizers and sterilization cycles which are used for medical purposes or for materials that are likely to come into contact with blood or body fluids.

This European Standard applies to automatically controlled small steam sterilizers that generate steam using electrical heaters or use steam that is generated by a system external to the sterilizer.

This European Standard applies to small steam sterilizers used primarily for the sterilization of medical devices with a chamber volume of less than 60l and unable to accommodate a sterilization module (300mm×300mm×600mm).

The requirements concerning the quality management and risk management are addressed by other standards (e.g. ENISO13485, ENISO14971).

This European Standard does not apply to small steam sterilizers that are used to sterilize liquids or pharmaceutical products.

This European Standard does not specify safety requirements related to risks associated with the zone in which the sterilizer is used (e.g. flammable gases).

This European Standard does not specify requirements for the validation and routine control of sterilization by moist heat.

NOTE Requirements for the validation and routine control of sterilization by moist heat are given in ENISO17665‑1.

This European Standard does not specify requirements for other sterilization processes that also employ moist heat as part of the process (i.e. formaldehyde, ethylene oxide).

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.