BS EN 1397:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Heat exchangers. Hydronic room fan coil units. Test procedures for establishing the performance

Available format(s)

Hardcopy , PDF

Withdrawn date

01-10-2021

Superseded by

BS EN 1397:2021

Language(s)

English

Published date

31-07-2016

€231.38
Excluding VAT

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Designation of fan coil units
5 Symbols
6 Air flow rate test for ducted units
7 Capacity rating tests
8 Performance tests
9 Test report
10 Manufacturer's data
Annex A (informative) - Drawings of the different types
        of configurations of fan coil units
Annex B (informative) - Air flow rate test for non-ducted units
Annex C (normative) - Design of separation partition for
        testing of cassette type fan coil units

Pertains to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating.

Committee
RHE/17
DevelopmentNote
Supersedes DD ENV 1397. (09/2005) Supersedes 13/30279266 DC. (08/2015)
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

This European Standard applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating. This European Standard covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120Pa max. This European Standard applies to all types of fan speed control of a fan coil unit (variable speed, multispeed). This European Standard deals with the cooling and heating functions of the FCU considered as an emitter for cooling/heating of a room/space. It does not cover any ventilation function of the unit. If the FCU can also provide fresh air, this function is not considered and the fresh air inlet closed during testing. This European Standard provides a method for the determination of the thermal performance of fan coil units in standard conditions, for the use with hot or chilled water or water mixtures. The test procedures given in this standard may additionally be used for determining performance at other conditions. It also provides the method for the determination of the air flow rate supplied by the fan coil unit. This standard does not cover the rating of heating or cooling from direct expansion coils or heating from electric resistance elements. The standard does not cover acoustic performance of fan coil units which is dealt with in EN16583 . It is not the purpose of this standard to specify the tests used for production or field testing. NOTE For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1.

ISO 5801:2017 Fans — Performance testing using standardized airways

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.