BS EN 15101-2:2013
Current
The latest, up-to-date edition.
Thermal insulation products for buildings. In-situ formed loose fill cellulose (LFCI) products Specification for the installed products
Hardcopy , PDF
English
30-09-2013
Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Requirements
5 Test methods
6 Guidelines for installation
7 Installer's declaration
Annex A (normative) - Open blow applications (lofts) -
Determination of installed insulation
thickness - Pin and plate method
Annex B (normative) - Cavity applications - Calculation for
determining the declared installed
insulation density in a construction
Annex C (normative) - Cavity applications - Determination of
average cavity width
Annex D (normative) - Cavity applications - Test box density
(method of checking the blown
density before installation into the wall)
Annex E (informative) - Example for installation guidelines
Bibliography
Describes requirements for in-situ formed loose-fill cellulose insulation (LFCI) products when installed as thermal insulation into walls, floors, galleries, roofs, lofts and ceilings.
Committee |
B/540
|
DevelopmentNote |
Supersedes 13/30258120 DC. (10/2013)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies requirements for in -situ formed loose-fill cellulose insulation (LFCI) products when installed as thermal insulation into walls, floors, galleries, roofs, lofts and ceilings.
This Part 2 is a specification for the installation checks for the installed products.It specifies the checks and tests to be used for the declarations made by the installer of the product.
This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.
Products with a declared thermal conductivity at 10 °C (mean temperature) greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard.
This European Standard does not cover factory made cellulose mats, bats or quilts intended to be used for the insulation of buildings or in-situ cellulose products for the insulation of building equipment and industrial installations. Nor does it specify performance requirements.
Standards | Relationship |
EN 15101-2:2013 | Identical |
PREN 15101-1 : DRAFT 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
EN 823:2013 | Thermal insulating products for building applications - Determination of thickness |