BS EN 16846-1:2017
Current
The latest, up-to-date edition.
Photocatalysis. Measurement of efficiency of photocatalytic devices used for the elimination of VOC and odour in indoor air in active mode Batch mode test method in closed chamber
Hardcopy , PDF
English
31-03-2017
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Apparatus
7 Test performance
8 Test report
Annex A (informative) - Schematic diagram of an
air tight chamber
Annex B (informative) - Types of sorbent apparatus
for thermal desorption cartridges
Annex C (informative) - Examples of a chamber
blanks analysis
Annex D (informative) - Analysis of the reaction
mixture
Annex E (informative) - Example of a plot of
temperature and relative humidity,
as well as developments in pollutants
and CO[2]
Annex F (informative) - Example of test at low
concentration with formaldehyde
Annex G (informative) - CADR calculation
Annex H (informative) - Calculation of CADR
Explains the methodologies to be used in a laboratory air tight chamber to test prototype or commercial air cleaner systems with a maximum flow rate of 1,000 m[3]/h used for photocatalytic indoor air remediation.
Committee |
RPI/13
|
DevelopmentNote |
Supersedes 15/30317868 DC. (03/2017)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard describes the methodologies to be used in a laboratory air tight chamber to test prototype or commercial air cleaner systems with a maximum flow rate of 1,000 m3/h used for photocatalytic indoor air remediation. It is applicable to the treatment of atmospheres that are representative of the air inside buildings and workplaces. This protocol is applicable solely to photocatalytic systems alone or to combined systems that include a photocatalytic function. The photocatalytic function is demonstrated by verifying the mineralization of model VOCs to form CO2.
Standards | Relationship |
EN 16846-1:2017 | Identical |
EN ISO 16017-1:2000 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000) |
ISO 16017-1:2000 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.