BS EN 1822-2:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High efficiency air filters (EPA, HEPA and ULPA) Aerosol production, measuring equipment, particle counting statistics
Hardcopy , PDF
22-10-2018
English
31-01-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Aerosol production
5 Measuring devices
6 Maintenance and inspection intervals
7 Particle counting statistics
Bibliography
Pertains to efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA) used in the field of ventilation and air conditioning and for technical processes, e.g. for applications in clean room technology or pharmaceutical industry.
Committee |
MCE/21
|
DevelopmentNote |
Supersedes 95/701889 DC. (06/2004)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard applies to efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA) used in the field of ventilation and air conditioning and for technical processes, e.g. for applications in clean room technology or pharmaceutical industry.
It establishes a procedure for the determination of the efficiency on the basis of a particle counting method using a liquid (or alternatively a solid) test aerosol, and allows a standardized classification of these filters in terms of their efficiency, both local and integral efficiency.
This European Standard describes the measuring instruments and aerosol generators used in the course of this testing. With regard to particle counting it specifies the statistical basis for the evaluation of counts with only small numbers of counted events.
Standards | Relationship |
NBN EN 1822-2 : 2010 | Identical |
SN EN 1822-2 : 2010 | Identical |
UNE-EN 1822-2:2010 | Identical |
NF EN 1822-2 : 2010 | Identical |
DIN EN 1822-2:2011-01 | Identical |
I.S. EN 1822-2:2009 | Identical |
ONORM EN 1822-2 : 2010 | Identical |
EN 1822-2:2009 | Identical |
NEN EN 1822-2 : 2009 | Identical |
UNI EN 1822-2 : 2010 | Identical |
NS EN 1822-2 : 2009 | Identical |
EN 1822-2 : 2019 | Identical |
PD 6609:2007 | Environmental cleanliness in enclosed spaces. Guide to in situ high efficiency filter leak testing |
EN 1822-5:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements |
VDI 3491 Blatt 1:2016-07 | Measurement of particles - Methods for generating test aerosols - Principles and overview |
VDI 3489 Blatt 2:1995-12 | Particulate matter measurement - Methods for characterizing and monitoring test aerosols - Continuous flow condensation nucleus counter |
VDI 2080:1996-04 | Measuring methods and measuring instruments for air-conditioning systems |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 14644-3:2005 | Cleanrooms and associated controlled environments Part 3: Test methods |
VDI 3489 Blatt 3:1997-03 | Particulate matter measurement - Methods of characterizing and monitoring test aerosols - Optical particle counter |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
VDI 3491 Blatt 5:1980-12 | Particulate matter measurement; generation of test aerosols by nebulization of dye-solutions with nozzle atomizers |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
VDI 3491 Blatt 7:1987-12 | Particulate matter measurement; generation of test aerosols; Rapaport-Weinstock generator |
EN 1822-1:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking |
EN 1822-4:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method) |
EN 14799:2007 | Air filters for general air cleaning - Terminology |
VDI 3491 Blatt 13:1996-06 | Particulate matter measurement - Generation of test aerosols using a vibrating-orifice generator |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.