Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Principle
5 Sampling
6 Analysis
7 Expression of results
8 Determination of the characteristics of the method:
  sampling and analysis
9 Measurement report
Annex A (informative) - Examples of absorbers
Annex B (informative) - Comparison between
        mercuric-thiocyanate spectrophotometry and ion
        exchange chromatography method (methods B and C)
Annex C (informative) - Example of assessment of
        compliance of the reference method for chlorides
Annex D (informative) - Performance characteristics of
        the whole measurement method
Annex E (informative) - Significant technical changes
Bibliography

Specifies the concentration of chlorinated compounds in a flue gas that - after passage of the sampling system including a particle filter - give Cl[-] ions in the absorption solution.

Committee
EH/2/1
DevelopmentNote
Supersedes BS EN 1911-1, BS EN 1911-2, BS EN 1911-3 & 08/30188440 DC. (09/2010)
DocumentType
Standard
Pages
50
PublisherName
British Standards Institution
Status
Current
Supersedes

The method described in this European Standard determines the concentration of chlorinated compounds in a flue gas that – after passage of the sampling system including a particle filter – give Cl- ions in the absorption solution. This Standard Reference Method has been evaluated during field tests on waste incineration. The method applies to waste gases in which chlorides concentration expressed as HCl may vary between 1 mg· m-3 and 5 000 mg· m-3 under normal pressure and temperature conditions (see Note 1), and according to emission limit values laid down, for example, in the Council Directive 2000/76/EC on waste incineration plants.

NOTE 1 The limit values of this European Standard are expressed in mg HCl/m3, on dry basis, at the reference conditions of 273 K and 101,3 kPa and at the reference O2 concentration.

NOTE 2 The required uncertainty results from the capacity of the method tested in the field (Annex D) and in the laboratory (see performance characteristics in Tables 1 and 2 and Annex C).

Standards Relationship
EN 1911:2010 Identical

CEN/TS 14793:2005 Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
ISO 10304-1:2007 Water quality Determination of dissolved anions by liquid chromatography of ions Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 13284-1:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)
EN ISO 10304-1:2009 Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate (ISO 10304-1:2007)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.