BS EN 1933:1999
Current
The latest, up-to-date edition.
Exterior blinds. Resistance to load due to water accumulation. Test method
Hardcopy , PDF
English
15-03-1999
1 Scope
2 Normative references
3 Definitions
3.1 water pocket
3.2 slope
3.3 drainage holes
3.4 projection
3.5 width
4 Test conditions
5 Equipment
5.1 Test rig
5.2 Watering spray pipe
5.3 Measuring equipment
6 Test sample dimensions
6.1 Folding and trellis arm blinds
6.2 Dutch awning
7 Tests
8 Expression of results
9 Test report
Details a test method for the determination of the ability of exterior blinds to resist loads caused by the retention of rain water by the fabric. Applies to exterior blinds forming an overhang when they are in extended position. These are: folding arm blind; trellis arm blind; adjustable or fixed Dutch awning.
Committee |
B/538
|
DevelopmentNote |
Supersedes 95/104340 DC (08/2004)
|
DocumentType |
Standard
|
Pages |
8
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NS EN 1933 : 1ED 1998 | Identical |
UNI EN 1933 : 2000 | Identical |
NBN EN 1933 : 1999 | Identical |
NF EN 1933 : 1999 | Identical |
I.S. EN 1933:1999 | Identical |
NEN EN 1933 : 1998 | Identical |
SN EN 1933 : 1999 | Identical |
EN 1933:1998 | Identical |
UNE-EN 1933:1999 | Identical |
DIN EN 1933:1999-03 | Identical |
PREN 12216 : DRAFT 2016 | SHUTTERS, EXTERNAL BLINDS, INTERNAL BLINDS - TERMINOLOGY, GLOSSARY AND DEFINITIONS |