Introduction
NA.1 Scope
NA.2 Nationally Determined Parameters
NA.3 Guidance on using informative annexes
NA.4 Reference to non-contradictory complementary
information
Bibliography
Provides: a) the UK decisions for the Nationally Determined Parameters described in the following subclauses of BS EN 1995-1-2:2004: (i) 2.1.3(2) (ii) 2.3(1)P (iii) 2.3(2)P (iv) 2.4.2(3) (v) 4.2.1(1) b) the UK decisions on the status of BS EN 1995-1-2:2004 informative annexes; c) reference to non-contradictory complementary information.
Committee |
B/525/5
|
DevelopmentNote |
This is a National Annex to BS EN 1995-1-2 To be used in conjunction with BS EN 1995-1-2, BS EN 1995-1-1, BS EN 1990, BS EN 1991 and their respective National Annexes. (10/2006) Supersedes 05/30134000 DC (11/2006) Also available as part of BS KIT 209. (08/2010)
|
DocumentType |
Standard
|
Pages |
10
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
BS 5268-4.1:1978 | STRUCTURAL USE OF TIMBER - PART 4: FIRE RESISTANCE OF TIMBER STRUCTURES - SECTION 4.1: RECOMMENDATIONS FOR CALCULATING FIRE RESISTANCE OF TIMBER MEMBERS |
BS 5268-4.2(1990) : 1990 | STRUCTURAL USE OF TIMBER - FIRE RESISTANCE OF TIMBER STRUCTURES - RECOMMENDATION FOR CALCULATING FIRE RESISTANCE OF TIMBER STUD WALLS AND JOISTED FLOOR CONSTRUCTIONS |
BS 5268-7.2:1989 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.2 JOISTS FOR FLAT ROOFS |
BS 5268-7.7:1990 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.7 PURLINS SUPPORTING SHEETING OR DECKING |
BS 5268-6.2(2001) : 2001 | STRUCTURAL USE OF TIMBER - PART 6: CODE OF PRACTICE FOR TIMBER FRAME WALLS - SECTION 6.2: BUILDINGS OTHER THAN DWELLINGS NOT EXCEEDING FOUR STOREYS |
BS 5268-7.4:1989 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.4: CEILING BINDERS |
BS 5268-7.1:1989 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.1 DOMESTIC FLOOR JOISTS |
BS 5268-7.6(1990) : 1990 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATION FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.6: PURLINS SUPPORTING RAFTERS |
BS EN 1995-1-1 : 2012 | EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-1: GENERAL - COMMON RULES AND RULES FOR BUILDINGS |
BS EN 1990:2002+A1:2005 | Eurocode. Basis of structural design |
BS 5268-7.5:1990 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.5: DOMESTIC RAFTERS |
BS 5268-7.3:1989 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATIONS FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.3: CEILING JOISTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.