• Shopping Cart
    There are no items in your cart

BS EN 334:2019

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Gas pressure regulators for inlet pressure up to 10 MPa (100 bar)

Available format(s)

Hardcopy , PDF

Withdrawn date

16-09-2024

Language(s)

English

Published date

03-09-2019

€385.64
Excluding VAT

This document specifies constructional, functional, testing, marking, sizing and documentation requirements of gas pressure regulators: — for inlet pressures up to 100 bar and nominal diameters up to DN 400; — for an operating temperature range from – 20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family as defined in EN 437:2018 [1], used in the pressure control stations in accordance with EN 12186 or EN 12279, in transmission and distribution networks and also in commercial and industrial installations.

Committee
GSE/32
DocumentType
Standard
ISBN
9780580925887
Pages
152
ProductNote
This standard also refers to EN 60534-2-1, EN 1092-3, EN 60534-3-1, EN 13445-4, BS EN 14382:2019, EN ISO 15614-2:2005/AC:2009.
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

This European Standard specifies constructional, functional, testing, marking, sizing and documentation requirements of gas pressure regulators: - for inlet pressures up to 100 bar and nominal diameters up to DN 400; - for an operating temperature range from - 20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family as defined in EN 437:2003+A1:2009, used in the pressure regulating stations in accordance with EN 12186 or EN 12279, in transmission and distribution networks and also in commercial and industrial installations. \'Gas pressure regulators\' hereafter will be called \'regulators\' except in the titles. For standard regulators when used in pressure regulating stations complying with EN 12186 or EN 12279, the Annex ZA lists all applicable essential safety requirements of the European legislation on pressure equipment except external and internal corrosion resistance for applications in corrosive environment. This document considers the following temperature classes/types of regulators: - temperature class 1: operating temperature range from ?10 °C to 60 °C; - temperature class 2: operating temperature range from ?20 °C to 60 °C; - type IS: (integral strength type); - type DS: (differential strength type). This document applies to regulators which use the pipeline gas as a source of control energy unassisted by any external power source. The regulator may incorporate a second regulator, used as monitor, complying with the requirements in this document. The regulator may incorporate a safety shut off device (SSD) complying with the requirements of EN 14382. The regulator may incorporate a creep (venting) relief device, complying with the requirements in Annex E and/or a vent limiter, complying with the requirements in Annex I. This document does not apply to: - regulators upstream from/on/in domestic gas-consuming appliances which are installed downstream of domestic gas meters; - regulators designed to be incorporated into pressure control systems used in service lines ) with volumetric flow rate ? 200 m3/h at normal conditions and inlet pressure ? 5 bar; - regulators for which a specific document exists (e.g. EN 88-1 and EN 88-2, etc.); - industrial process control valves in accordance with EN 1349. The normative Annex G of this document lists some suitable materials for pressure bearing parts, inner metallic partition walls, auxiliary devices, integral process and sensing lines, connectors and fasteners. Other materials may be used when complying with the restrictions given in Table 5. Continued integrity of gas pressure regulators is ensured by suitable surveillance checks and maintenance. For periodic functional checks and maintenance it is common to refer to national regulations/standards where existing or users/manufacturers practices. This document has introduced the reaction of the pressure regulators to the specified reasonable expected failures in terms of \'fail close\' and \'fail open\' pressure regulator types, but it should be considered that there are other types of failures whose consequences can bring to the same reactions (these risks are covered via redundancy as per EN 12186) and that residual hazards will be reduced by a suitable surveillance in use / maintenance. In this document, both pressure regulators that can be classified as \'safety accessories\' by themselves (monitors) according to European legislation on pressure equipment as well as regulators that can be used to provide the necessary pressure protection through redundancy (e.g. pressure regulator with integrated safety shut-off device, pressure regulator + in-line monitor, pressure regulator + safety shut off device) are considered. The provisions in this document are in line with the state of art at the moment of writing.

Standards Relationship
EN 334:2019 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.