BS EN 404:2005
Current
The latest, up-to-date edition.
Respiratory protective devices for self-rescue. Filter self-rescuer from carbon monoxide with mouthpiece assembly
Hardcopy , PDF
English
02-05-2005
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Description
5 Classification
6 Requirements
6.1 General
6.2 Ergonomics
6.3 Design
6.4 Materials
6.5 Cleaning and disinfecting
6.6 Mass
6.7 Connections
6.8 Means of carrying
6.9 Harness
6.10 Handling
6.11 Leak tightness
6.12 Facepiece
6.12.1 Mouthpiece assembly
6.12.2 Breathing hose
6.13 Inhalation and exhalation valves
6.14 Saliva trap
6.15 Integrity of device at high carbon monoxide concentrations
6.16 Conditioning
6.16.1 Mechanical strength
6.16.2 Rough usage (optional)
6.16.3 Temperature
6.16.4 Transport
6.17 Carbon dioxide content of inhalation air (dead space)
6.18 Performance requirements
6.18.1 Minimum test duration
6.18.2 Carbon monoxide - breakthrough criteria
6.18.3 Temperature and humidity
6.18.4 Breathing resistance
6.19 Practical performance
7 Testing
7.1 General
7.2 Nominal values and tolerances
7.3 Visual Inspection
7.4 Conditioning
7.4.1 General
7.4.2 Mechanical strength test
7.4.3 Rough usage test
7.4.4 Temperature conditioning
7.5 Practical performance test
7.5.1 Escape test
7.5.2 Transport test
7.6 Laboratory test
7.6.1 Protection against carbon monoxide
7.6.2 Testing at high CO concentrations
7.6.3 Breathing resistance
7.6.4 Leak tightness
7.6.5 Materials
7.6.6 Insulation resistance of non-metallic carrying
containers
7.6.7 Inhalation and exhalation valves
7.6.8 Carbon dioxide content of inhalation air
(dead space)
7.6.9 Breathing hoses
7.6.10 Pull test and tear-off force
8 Marking
8.1 General
9 Information supplied by the manufacturer
Annex A (normative) Methods of measurement of the insulation
resistance of non-metallic carrying
containers
A.1 Voltmeter ammeter method
A.2 Comparative method
Annex B (informative) Method for the determination of wet
bulb temperature of the inhaled air
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements
of EU Directive 89/686/EEC Personal
Protective Equipment
Relates to filtering devices designed for protection against carbon monoxide (filter self-rescuer). Specifies minimum requirements for filter self-rescuers.
Committee |
PH/4
|
DevelopmentNote |
Supersedes 90/45548 DC and 02/562273 DC (05/2005)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NS EN 404 : 2ED 2005 | Identical |
EN 404:2005 | Identical |
NEN EN 404 : 2005 | Identical |
UNI EN 404 : 2006 | Identical |
NF EN 404 : 2005 | Identical |
UNE-EN 404:2005 | Identical |
SN EN 404 : 2005 | Identical |
NBN EN 404 : 2005 | Identical |
I.S. EN 404:2005 | Identical |
DIN EN 404:2005-07 | Identical |
EN 132:1998 | Respiratory protective devices - Definitions of terms and pictograms |
EN 134:1998 | Respiratory protective devices - Nomenclature of components |
EN 13274-2:2001 | Respiratory protective devices - Methods of test - Part 2: Practical performance tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.