• BS EN 50107-2:2005

    Current The latest, up-to-date edition.

    Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Requirements for earth-leakage and open-circuit protective devices

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  29-04-2005

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 General requirements
    5 Tests
    6 Classification
    7 Marking
       7.1 Items of marking
       7.2 Durability of marking
       7.3 Additional information
    8 Terminals
    9 Provision for protective earthing
    10 Protection against accidental contact with live parts
    11 Moisture resistance and insulation of type B devices
    12 Electric strength
    13 Thermal endurance of devices
       13.1 General
       13.2 Tests for type B devices
       13.3 Tests for type A or type C devices
    14 Fault conditions
    15 Construction
    16 Creepage distances and clearances
    17 Screws, current-carrying parts and connections
    18 Resistance to heat, fire and tracking
    19 Resistance to corrosion
    20 Performance
       20.1 Performance requirements for earth-leakage
            protective devices
       20.2 Performance requirements for open-circuit
            protective devices
       20.3 Performance requirements common to both types
            of device
    21 Interchangeability
    Annex A (normative) - Testing of the response time of
                            earth-leakage protective devices
    Annex B (informative) - An example method of measuring the
                            performance of an earth-leakage
                            protective device
    Annex C (normative) - Test of the response time of
                            open-circuit protective devices
    Annex D (informative) - A method of measuring the performance
                            of an open-circuit protective device

    Abstract - (Show below) - (Hide below)

    Defines requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformers conforming to EN 61050 at voltages exceeding 1 000 V but not exceeding 10 000 V.

    Scope - (Show below) - (Hide below)

    This European Standard specifies requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformers conforming to EN 61050 at voltages exceeding 1 000 V but not exceeding 10 000 V. NOTE 1 Requirements for the installation of earth-leakage and open-circuit protective devices are given in EN 50107-1. NOTE 2 Requirements for earth-leakage and open-circuit protective devices used with inverters and converters are specified in EN 61347-2-10.

    General Product Information - (Show below) - (Hide below)

    Committee CPL/34/11
    Development Note Supersedes 01/206090 DC. (05/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50107-1 : 2002 AMD 1 2004 SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1 KV BUT NOT EXCEEDING 10 KV - PART 1: GENERAL REQUIREMENTS
    EN 61050:1992/A1:1995 TRANSFORMERS FOR TUBULAR DISCHARGE LAMPS HAVING A NON LOAD OUTPUT VOLTAGE EXCEEDING 1000 V (GENERALLY CALLED NEON TRANSFORMERS - GENERAL AND SAFETY REQUIREMENTS
    IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
    EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective