• Shopping Cart
    There are no items in your cart

BS EN 50124-2:2017

Current

Current

The latest, up-to-date edition.

Railway applications. Insulation coordination Overvoltages and related protection

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-2017

€156.59
Excluding VAT

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and Definitions
4 Contact line network
5 Train line network
6 Tests
Annex A (informative) - Maximum value of voltage
        U according to duration
Annex ZZ (informative) - Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 2008/57/EC
Bibliography

Pertains to: - fixed installations (downstream of the secondary of the substation transformer) and rolling stock equipment linked to the contact line of one of the systems defined in EN 50163; - rolling stock equipment linked to a train line.

Committee
GEL/9
DevelopmentNote
Supersedes 96/209091 DC. (09/2005) Supersedes 15/30298492 DC. (03/2017)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard applies to: fixed installations (downstream of the secondary of the substation transformer) and rolling stock equipment linked to the contact line of one of the systems defined in EN50163 ; rolling stock equipment linked to a train line. This European Standard gives simulation and/or test requirements for protection against transient overvoltages of such equipment. Long-term overvoltages are not addressed in this document.

Standards Relationship
SN EN 50124-2 : 2017 Identical
EN 50124-2:2017 Identical
NBN EN 50124-2 : 2001 Identical
I.S. EN 50124-2:2017 Identical
NEN EN 50124-2 : 2017 Identical
UNE-EN 50124-2:2001 Identical
UNE-EN 50124-2:2017 Identical
NF EN 50124-2 : 2018 Identical
DIN EN 50124-2 : 2017 Identical

IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 50526-1:2012 Railway applications - Fixed installations - D.C. surge arresters and voltage limiting devices - Part 1: Surge arresters
2008/57/EC : 2008 AMD 5 2014 DIRECTIVE 2008/1957/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 17 JUNE 2008 ON THE INTEROPERABILITY OF THE RAIL SYSTEM WITHIN THE COMMUNITY (RECAST) (TEXT WITH EEA RELEVANCE)
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 50533 : 2011 AMD 1 2016 RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
UIC 550 : 11ED 2005 POWER SUPPLY INSTALLATIONS FOR PASSENGER STOCK
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.