BS EN 50131-2-3:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Alarm systems. Intrusion and hold-up systems Requirements for microwave detectors
Hardcopy , PDF
30-03-2022
English
31-05-2014
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions & requirements of
the standardised test magnets
Annex B (normative) - General testing matrix
Annex C (informative) - Walk test diagrams
Annex D (informative) - Equipment for walk test
velocity control
Annex E (informative) - Immunity to microwave
signal interference by fluorescent lights
Annex F (informative) - Example list of small tools
Annex G (normative) - Test for resistance to
re-orientation of djustable mountings
Bibliography
National Annex NA (Informative) - Text of IS1 to
EN 50131-2-3:2008
Details for microwave detectors installed in buildings and provides for security grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV.
Committee |
GW/1/1
|
DevelopmentNote |
Supersedes DD CLC/TS 50131-2-3 & 07/30162638 DC. (01/2009)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This European Standard is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for microwave detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The standard does not apply to system interconnections.
Standards | Relationship |
EN 50131-2-3:2008/IS1:2014 | Identical |
EN 50131-2-3:2008 | Identical |
PD 6662:2010 | Scheme for the application of European standards for intrusion and hold-up alarm systems |
PD 6662:2017 | Scheme for the application of European Standards for intrusion and hold-up alarm systems |
09/30203716 DC : 0 | PD 6662 - SCHEME FOR THE APPLICATION OF EUROPEAN STANDARDS FOR INTRUSION AND HOLD-UP ALARM SYSTEMS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60404-8-1:2015 | Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60404-5:2015 RLV | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
EN 60404-5:2015 | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.