BS EN 50131-2-6:2008
Current
The latest, up-to-date edition.
Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic)
Hardcopy , PDF
English
31-05-2014
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions & requirements
of standardized interference test magnets
Annex B (normative) - General testing matrix
Annex C (informative) - List of small tools suitable
for testing immunity of casing to unauthorised
access
Annex D (normative) - Axes of movement
Annex E (normative) - Test surfaces for ferromagnetic material
Annex F (normative) - Test faces for interference test magnets
Bibliography
National Annex NA (Informative) - Text of IS1 to
EN 50131-2-6:2008
Presents for security grades 1 to 4, specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Committee |
GW/1/1
|
DevelopmentNote |
Supersedes DD CLC/TS 50131-2-6 & 07/30170080 DC. (01/2009)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes | |
UnderRevision |
This European Standard provides for security grades1 to 4, (see EN50131-1) specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN50130-5.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions.
The two separate parts of the opening contact (magnetic) shall be referred to in the body of this European Standard as the detector.
This European Standard does not apply to system interconnections.
Standards | Relationship |
EN 50131-2-6:2008/IS1:2014 | Identical |
EN 50131-2-6:2008 | Identical |
PD 6662:2010 | Scheme for the application of European standards for intrusion and hold-up alarm systems |
PD 6662:2017 | Scheme for the application of European Standards for intrusion and hold-up alarm systems |
09/30203716 DC : 0 | PD 6662 - SCHEME FOR THE APPLICATION OF EUROPEAN STANDARDS FOR INTRUSION AND HOLD-UP ALARM SYSTEMS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 60404-8-1:2015 | Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60404-5:2015 RLV | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 10130:2006 | Cold rolled low carbon steel flat products for cold forming - Technical delivery conditions |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
EN 60404-5:2015 | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-