    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Reference architecture
    5 Relation between the characteristics of the
       transmission systems and safety procedures
    6 Safety procedure requirements
    7 Safety code requirements
    Annex A (informative) - Length of safety code
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EC Directives

    Abstract - (Show below) - (Hide below)

    Provides the basic requirements needed in order to achieve safety-related communication between safety related equipment connected to the transmission system.

    Scope - (Show below) - (Hide below)

    This European Standard is applicable to safety-related electronic systems using a closed transmission system for communication purposes. It gives the basic requirements needed in order to achieve safety-related communication between safety-related equipment connected to the transmission system.

    This standard is applicable to the safety requirement specification and design of the communication system in order to obtain the assigned safety integrity level (SIL).

    The safety requirement specification is a precondition of the safety case of a safety-related electronic system for which the required evidence is defined in EN 50129. Evidence of safety management and quality management has to be taken from EN 50129. Evidence of functional and technical safety is the subject of this standard.

    This standard is not applicable to existing systems which had already been accepted prior to the release of this standard. However, as far as is reasonably practicable, this standard shall be applied to modifications and extensions to existing systems, subsystems and equipment.

    This standard applies to a closed transmission system with the following preconditions, for which evidence shall be provided.

    1. Only approved access is permitted.

    2. There is a known maximum number of connectable participants.

    3. The transmission media is known and fixed.

    Closed transmission systems are not necessarily data buses. They can also include for instance balise links or simple serial links between two safety-related computers.

    In particular this standard does not define the following.

    • The transmission system.

    • The equipment connected to the transmission system.

    • Specific solutions (e.g. for interoperability).

    • Which kinds of data are safety-related and which aren’t.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/9
    Development Note Supersedes 94/209610 DC. (09/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50128:2011/AC:2014 RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - SOFTWARE FOR RAILWAY CONTROL AND PROTECTION SYSTEMS
    ENV 50129 : DRAFT 98 RAILWAY APPLICATIONS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING
    EN 50126 : 1999 RAILWAY APPLICATIONS - THE SPECIFICATION AND DEMONSTRATION OF RELIABILITY, AVAILABILITY, MAINTAINABILITY AND SAFETY (RAMS)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective