BS EN 50268-1:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Apparatus

Available format(s)

Hardcopy , PDF

Superseded date

04-01-2006

Language(s)

English

Published date

15-04-2000

€140.23
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Definitions
4 Details of test enclosure
5 Photometric system
6 Standard fire source
7 Smoke mixing
8 Blank test
      8.1 Purpose
      8.2 Procedure
9 Qualification of test apparatus
10 Qualification burning test
      10.1 Purpose
      10.2 Preparation of cube
      10.3 Qualification smoke sources
      10.4 Test procedure
      10.5 Calculation
      10.6 Requirements
Annex A (informative) Guidance notes
Annex B (informative) Bibliography

Specifies method of test for measurement of smoke density of insulated conductors or cables, or optical cables, burning under defined conditions.

Committee
GEL/20/18
DevelopmentNote
Supersedes BS 7622-1(1993). (03/2000) Supersedes 96/206669 DC. (09/2005)
DocumentType
Standard
Pages
10
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
I.S. EN 50268-1:1999 Identical
UNE-EN 50268-1:2000 Identical
EN 50268-1:1999 Identical
SN EN 50268-1 : 1999 Identical
DIN EN 50268-1 : 2000 Identical
NEN EN 50268-1 : 1999 Identical
NF EN 50268-1 : 2000 Identical
NBN EN 50268-1 : 2000 Identical

BS 7870-3.50:2005 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603)
BS 8436:2004 Electric cables. 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables
BS PAS 40(2002) : 2002 BANKNOTE THEFT DETERRENT SYSTEMS USING DYE OR SMOKE-DYE
BS 7870-3.12:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV - XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
BS 7846:2000 Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire
BS 7346-6:2005 Components for smoke and heat control systems Specifications for cable systems
05/30126924 DC : DRAFT MAY 2005 BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries

IEC 60879:1986 Performance and construction of electric circulating fans and regulators
EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.