BS EN 50288-12-1:2017
Current
The latest, up-to-date edition.
Multi-element metallic cables used in analogue and digital communications and control Sectional specification for screened cables characterised from 1 MHz up to 2 000 MHz. Horizontal and building backbone cables
Hardcopy , PDF
English
19-09-2017
European foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols
and abbreviations
4 Cable construction
5 Test methods and requirements for
completed cables
Annex A (normative) - Maximum voltage, current
and temperature rating for cables used
for POE applications (ffs)
Annex B (informative) - Blank Detail Specification
Bibliography
Defines sectional specification for screened cables, characterised up to 2000 MHz, to be used in horizontal and building backbone wiring for information technology, generic-cabling systems. Also covers the electrical, mechanical, transmission and environmental performance characteristics and requirements of the cables when tested in accordance with the referenced test methods.
| Committee |
EPL/46
|
| DevelopmentNote |
Supersedes 16/30331040 DC. (10/2017)
|
| DocumentType |
Standard
|
| Pages |
22
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
EN 50288-12-1 is a sectional specification for screened cables, characterised up to 2 000 MHz, to be used in horizontal and building backbone wiring for information technology, generic-cabling systems.
This sectional specification contains the electrical, mechanical, transmission and environmental performance characteristics and requirements of the cables when tested in accordance with the referenced test methods.
This sectional specification is to be read in conjunction with EN 50288-1, which contains the essential provisions for its application.
The cables covered in this sectional specification are intended to operate with voltages and currents normally encountered in communications systems. These cables are not intended to be used in conjunction with low impedance sources, for example the electrical power supplies of public utility mains.
| Standards | Relationship |
| EN 50288-12-1:2017 | Identical |
| I.S. EN 50288-12-1:2017 | Equivalent |
| EN 60708:2005/AC:2016-08 | LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH |
| EN 50288-1:2013 | Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification |
| IEC 60189-2:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations |
| IEC 60708:2005 | Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.