• BS EN 50306-2:2002

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables

    Available format(s):  Hardcopy, PDF

    Superseded date:  10-04-2020

    Language(s):  English

    Published date:  13-11-2002

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Single core cables
    4 Tests
    Annex A (informative) Guidance on selection of cables
            for type approval
    Annex B (informative) Bibliography
    Tables

    Abstract - (Show below) - (Hide below)

    Gives requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm[2] to 2,5 mm[2] single core).

    Scope - (Show below) - (Hide below)

    EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-11). NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1. NOTE 3 EN 45545-1 is still under development and should be consulted. EN 50306-2 should be used in conjunction with EN 50306-1, General requirements.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/12
    Development Note Supersedes 01/206814 DC (11/2002)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
    IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
    EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
    EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
    EN 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
    EN 45545-1 : 2013 COR 2013 RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL
    EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
    EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
    EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
    EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
    IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
    EN 50334:2001 Marking by inscription for the identification of cores of electric cables
    IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
    EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
    EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
    EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective