BS EN 50341-2-18:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Overhead electrical lines exceeding AC 1 kV National Normative Aspects (NNA) for Sweden (based on EN 50341-1:2012)
Hardcopy , PDF
07-08-2023
English
31-03-2017
Foreword
1 Scope
2 Normative references, definitions
and symbols
3 Basis of design
4 Actions on lines
5 Electrical requirements
6 Earthing systems
7 Supports
8 Foundations
9 Conductors and earth-wires
10 Insulators
11 Hardware
12 Quality assurance, Checks and taking-over
Annex E - Electrical requirements
Annex G - Earthing systems
Annex J - Lattice steel towers
Annex K - Steel poles
Annex M - Geotechnical and structural
design of foundations
Pertains to for new overhead lines only and not for existing lines.
Committee |
PEL/11
|
DevelopmentNote |
Supersedes BS EN 50423-3 & BS EN 50341-3, which remain current. (04/2017)
|
DocumentType |
Standard
|
Pages |
90
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
SE.1 Application to existing overhead lines This Part 2-18 is applicable for new overhead lines only and not for existing lines. SE.2 Maintenance, rebuilding or extension of an overhead line Measures related to maintenance of the electrical installation shall fulfill the legislation in force when it was erected. In the case of a rebuilding or extension of an electrical installation (overhead line), the regulations in force shall be applied for the rebuilding or extension. (ELSÄK-FS 2008:1) SE.3 Replacement This Part 2-18 replaces the Swedish Standards SS EN 50341 3 18, edition 1 and SS EN 50423 3 18, edition 3. SE.4 Optical ground wire (OPGW) and optical phase conductor (OPCON) This Part 2-18 is applicable for installation of OPGW and OPCON, also known as OPPC, in overhead lines in Sweden. SE.5 All dielectric self supporting optical cable (ADSS) and optical attached cable (OPAC) This Part 2-18 is applicable for installation of ADSS and OPAC in overhead lines in Sweden. NOTE The allowable electrical field for the ADSS cable should be taken into consideration when the conductor configuration is determined.
Standards | Relationship |
EN 50341-2-18:2016 | Identical |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.