• BS EN 50402:2017

    Current The latest, up-to-date edition.

    Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen. Requirements on the functional safety of gas detection systems

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-03-2017

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    European foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 Functional modules and elements - Characterization
       and requirements
    6 Software
    7 Combining Functional Modules to Safety Functions
    8 Determination of hardware failure rates for each safety
       function
    9 Gas detection as part of an overall safety function
    10 Information requirements
    11 Validation
    12 Functional safety management
    13 Functional safety assessment
    14 Documentation
    Annex A (normative) - Transformation of the
            SIL-capabilities of gas detection systems
    Annex B (normative) - Transformation from generic
            standard requirements to modules
    Annex C (informative) - Determination of SIL-capability
            of a safety function of the gas detection system
    Annex D (informative) - Failure modes for specific
            measuring principles

    Abstract - (Show below) - (Hide below)

    Pertains to detection and measurement apparatus and systems for flammable or toxic gases or vapours or oxygen.

    Scope - (Show below) - (Hide below)

    This European Standard is applicable to detection and measurement apparatus and systems for flammable or toxic gases or vapours or oxygen. It covers apparatus intended to measure reliably, gas concentration and to provide an output signal (alarm and/or measurement signal), the purpose of which is to give a warning of a potential hazard.

    This European Standard is a product standard which is based on EN 61508 (all parts) and for gas detection systems covers both low and high demand mode at SIL capabilities of 1, 2 or 3 only. Gas detection apparatus and gas detection systems are developed as generic products. This European Standard covers part of the phase 10 “realization?? of the overall safety lifecycle defined in EN 61508-1:2010, Figure 2. Configuration and integration into specific applications is not covered by this European Standard.

    In the event of conflict between the requirements of this European Standard and those of EN 61508, EN 50402 will take precedence.

    NOTE 1 Applications requiring a SIL capability of 4 for a gas detection system are not practicable.

    This European Standard is dedicated mainly to fixed apparatus and systems. However, it can also be applied to transportable gas detectors which are intended to be used as temporary replacements for fixed apparatus.

    This European Standard supplements the requirements of the European Standards for electrical apparatus for the detection and measurement of flammable gases, vapours (e.g. EN 60079-29-1 or EN 60079-29-4), toxic gases (e.g. EN 45544) or oxygen (e.g. EN 50104).

    NOTE 2 These European Standards are called in the text “metrological standards??.

    The examples above show the state of the standardization for industrial applications at the time of publishing this European Standard. There may be other metrological standards covering other application fields, for which this European Standard is also applicable.

    EN 50271 specifies minimum requirements for apparatus using software and/or digital components. It also defines additional optional requirements for compliance with SIL 1 in low demand mode operation. EN 50402 includes all requirements of EN 50271.

    EN 50402 is also dedicated to apparatus and gas detection systems and/or components and should be used instead of EN 50271 in the following cases:

    • at SIL 1 when the system contains components not covered by EN 50271;

    • at SIL 1 high demand mode operation;

    • at SIL 2 and SIL 3;

    • at all SILs when non-digital based apparatus is used.

    Applying the above-mentioned metrological standards will ensure the performance is adequate in normal operation of a gas detection system. Additionally, the requirements of this European Standard address the functional safety of gas detection systems and encompass criteria for reliability, fault tolerance and avoidance of systematic failures. The avoidance and control of systematic failures will be covered by the requirements for the development processes and techniques and diagnostic measures chosen in the design. This European Standard will lead to the characterization of the gas detection system by a SIL-capability and related hardware failure rate representing a hierarchical order of safety levels. This will allow the user to incorporate the gas detection system into an overall safety system according to the safety integrity levels of EN 61508 (all parts).

    This European Standard is applicable for gas detection systems, which may consist of the following functional units:

    • gas-sampling;

    • sensor;

    • signal transmission;

    • input to control unit;

    • signal processing in control unit;

    • output from control unit.

    This European Standard does not specify requirements for the installation and maintenance of gas detection systems. It also does not specify the physical positioning of measuring points / locations.

    This European Standard does not specify which SIL-capability is sufficient for which application.

    NOTE 3 The SIL-capability required for an application will be specified by the user (see Clause 9 and Annex A).

    General Product Information - (Show below) - (Hide below)

    Committee EXL/31/1
    Development Note Supersedes 04/30115623 DC. (01/2006) Supersedes 07/30168062 DC. (06/2009) Supersedes 13/30260728 DC. (03/2017)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3
    EN 50270:2015 Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
    EN 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements
    EN 50104:2010 Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
    EN 61326-3-2:2008 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
    IEC 61326-3-2:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment
    IEC 60158-2:1982 Low-voltage controlgear. Part 2: Semiconductor contactors (solid state contactors)
    EN 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements
    EN 60079-29-4:2010 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    EN 45544-3 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION
    EN 61784-3:2016/A1:2017 INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3: FUNCTIONAL SAFETY FIELDBUSES - GENERAL RULES AND PROFILE DEFINITIONS (IEC 61784-3:2016/A1:2017)
    EN 45544-1:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 1: General requirements and test methods
    EN 60079-29-1:2016 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
    EN 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures
    IEC 61326-3-2 : 2.0 ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - EMC REQUIREMENTS - PART 3-2: IMMUNITY REQUIREMENTS FOR SAFETY-RELATED SYSTEMS AND FOR EQUIPMENT INTENDED TO PERFORM SAFETY-RELATED FUNCTIONS (FUNCTIONAL SAFETY) - INDUSTRIAL APPLICATIONS WITH SPECIFIED ELECTROMAGNETIC ENVIRONMENT
    IEC 60079-29-3:2014 Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems
    IEC 61508-5:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508)
    IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
    IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
    IEC 60079-29-4:2009 Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
    EN 45544-2:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement
    EN 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems
    EN 45544-4 : 2016 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 4 - GUIDE FOR SELECTION, INSTALLATION, USE AND MAINTENANCE
    IEC 60079-29-2:2015 RLV Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    EN 50271:2010 Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies
    EN 61508-5:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels
    EN 45544-1:2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS
    EN 45544-3:2015 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection
    IEC 61508-6:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)
    IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
    EN 60079-29-2:2015 Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
    IEC 61508-7:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508)
    EN 60079-29-3:2014 Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems
    EN 61326-3-1:2017 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - General industrial applications
    EN 45544-4:2016 Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 4: Guide for selection, installation, use and maintenance
    IEC 61784-3:2016+AMD1:2017 CSV Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions
    EN 50159:2010 Railway applications - Communication, signalling and processing systems - Safety-related communication in transmission systems
    EN 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations
    EN 45544-2 : 2015 WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective