BS EN 50561-3:2016
Current
The latest, up-to-date edition.
Power line communication apparatus used in low-voltage installations. Radio disturbance characteristics. Limits and methods of measurement Apparatus operating above 30 MHz
Hardcopy , PDF
English
31-01-2016
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Compliance with this standard
5 Requirements for the frequency range below 30 MHz
6 Requirement for the frequency range above 30 MHz
7 Measurement conditions for PLC ports
8 Measurement Uncertainty
Annex A (normative) - Excluded frequency ranges
Annex B (normative) - Example of test arrangement
Annex C (informative) - Rationale for the use of conducted
and radiated measurement methods13
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Bibliography
Defines limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low voltage power installation as the transmission medium.
Committee |
GEL/210
|
DevelopmentNote |
Supersedes 14/30281719 DC. (02/2016)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of EN50561 specifies limits and methods of measurement of radio disturbance characteristics for in-home communication apparatus that use the low voltage power installation as the transmission medium. This part of EN50561 applies to equipment that uses frequencies including those above 30MHz in order to communicate. Procedures are given for the measurement of signals generated by the equipment and limits are specified within the frequency range 9kHz to 400GHz. No measurement is required at frequencies where no limits are specified. The radiated emission requirements in this standard are not intended to be applicable to the intentional transmissions from a radio-transmitter as defined by the ITU, nor to any spurious emissions related to these intentional transmissions. NOTE The requirements defined in this standard effectively restrict the intended transmission frequencies to below 87,5MHz.
Standards | Relationship |
EN 50561-3:2016 | Identical |
EN 50561-1:2013/AC:2015 | Power line communication apparatus used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 1: Apparatus for in-home use |
CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 32:2015 RLV | Electromagnetic compatibility of multimedia equipment - Emission requirements |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription