EN 50525-2-21:2011/AC:2013
|
ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
IEC 60079-1:2014 RLV
|
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60038:2009
|
IEC standard voltages |
ISO 7010:2011
|
Graphical symbols Safety colours and safety signs Registered safety signs |
EN 50264-3-1:2008
|
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
EN 60079-1:2014
|
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
IEC 60502-2:2014 RLV
|
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) |
EN 60079-10-1:2015
|
Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
IEC 60364-4-41:2005+AMD1:2017 CSV
|
Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60079-0:2012/A11:2013
|
EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 60332-2-2:2004
|
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
HD 631.1 : 200S2
|
ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS |
IEC 61557-15:2014
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
IEC 60502-1:2004+AMD1:2009 CSV
|
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) |
IEC 60204-1:2016
|
Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
EN 60794-1-1:2016
|
Optical fibre cables - Part 1-1: Generic specification - General |
HD 60364-4-41:2017/A11:2017
|
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 60332-2-2:2004
|
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
EN 61099:2010
|
Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
EN 60079-10-2:2015
|
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres |
IEC 60079-10-1:2015
|
Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 50525-2-81:2011
|
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding |
IEC 60794-1-1:2015
|
Optical fibre cables - Part 1-1: Generic specification - General |
EN 50290-2-23:2013
|
COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
IEC 61099:2010
|
Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 60332-1-1:2004+AMD1:2015 CSV
|
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus |
EN 50525-2-31:2011
|
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation |
IEC 60332-1-2:2004+AMD1:2015 CSV
|
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60836:2015
|
Specifications for unused silicone insulating liquids for electrotechnical purposes |
EN 50525-1:2011
|
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
EN 60079-11:2012
|
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60296:2012 RLV
|
Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60079-11:2011
|
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60865-1:2011
|
Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
EN 60332-1-1:2004/A1:2015
|
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus |
EN 60296:2012
|
Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60079-25:2010/AC:2013
|
EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV
|
Degrees of protection provided by enclosures (IP Code) |
EN 60836:2015
|
Specifications for unused silicone insulating liquids for electrotechnical purposes |
EN 60865-1:2012
|
Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
IEC 60079-25:2010
|
Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
EN 50288-1:2013
|
Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification |
EN 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60079-0:2011
|
Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60909:1988
|
Short-circuit current calculation in three-phase a.c. systems |
IEC 60079-14:2013
|
Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 60332-2-1:2004
|
Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus |
EN 60079-14:2014/AC:2016
|
EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
EN 60332-2-1:2004
|
Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus |
EN 61557-6:2007
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems |
EN 50290-2-22 : 2001 AMD 1 2007
|
COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS |
EN 50363-1:2005
|
Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds |
EN 60529:1991/AC:2016-12
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 61557-15:2014
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems |
EN 61557-8:2015/AC:2016-06
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-8:2014
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-6:2007
|
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV
|
Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 50303:2000
|
Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust |
EN 50290-2-21:2001/A1:2007/AC:2016
|
COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATING COMPOUNDS |
EN 61557-9:2015/AC:2017-02
|
ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
EN 50393:2015
|
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV |
EN 60038 : 2011
|
CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
IEC 60364-5-52:2009
|
Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
EN 60204-1 : 2006 COR 2010
|
SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
EN 60309-1:1999/A1:2007/AC:2014
|
PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012) |