BS EN 54-3:2014
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Fire detection and fire alarm systems Fire alarm devices. Sounders
Hardcopy , PDF
English
31-10-2014
26-04-2019
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Sound pressure level for fire alarm sounders
Annex B (normative) - Comparative sound pressure level test during
environmental conditioning
Annex C (informative) - Data supplied with sounders
Annex D (informative) - Sound patterns used in some European countries
Annex E (informative) - Comparison of flammability test requirements
in various standards
Annex ZA (informative) - Clauses of this European Standard addressing
the provisions of the EU Construction Products Regulation
Bibliography
Describes the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building.
| Committee |
FSH/12/5
|
| DevelopmentNote |
Supersedes 95/542860 DC. (09/2002) Supersedes 01/541337 DC. (03/2003) Supersedes 04/30109692 DC. (09/2007) Supersedes 09/30184483 DC. (10/2014)
|
| DocumentType |
Standard
|
| Pages |
76
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011). This European standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN. This European standard is not intended to cover: a) loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source; b) supervisory sounders, for example, within the control and indicating equipment.
| Standards | Relationship |
| ONORM EN 54-3 : 2014 | Identical |
| NBN EN 54-3 : 2014 | Identical |
| NEN EN 54-3 : 2014+A1:2019 | Identical |
| I.S. EN 54-3:2014 | Identical |
| EN 54-3:2014 | Identical |
| NF EN 54-3 : 2014 | Identical |
| DIN EN 54-3:2014-09 | Identical |
| NS EN 54-3 : 2014 | Identical |
| UNE-EN 54-3:2016 | Identical |
| DIN EN 54-3:2001-10 | Identical |
A newer version of this standard is available.