BS EN 54-3:2014

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Fire detection and fire alarm systems Fire alarm devices. Sounders

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-2014

Withdrawn date

26-04-2019

Superseded by

BS EN 54-3:2014+A1:2019

€356.52
Excluding VAT
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of performance (AVCP)
7 Classification and designation
8 Marking, labelling and packaging
Annex A (normative) - Sound pressure level for fire alarm sounders
Annex B (normative) - Comparative sound pressure level test during
        environmental conditioning
Annex C (informative) - Data supplied with sounders
Annex D (informative) - Sound patterns used in some European countries
Annex E (informative) - Comparison of flammability test requirements
        in various standards
Annex ZA (informative) - Clauses of this European Standard addressing
         the provisions of the EU Construction Products Regulation
Bibliography

Describes the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building.

Committee
FSH/12/5
DevelopmentNote
Supersedes 95/542860 DC. (09/2002) Supersedes 01/541337 DC. (03/2003) Supersedes 04/30109692 DC. (09/2007) Supersedes 09/30184483 DC. (10/2014)
DocumentType
Standard
Pages
76
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011). This European standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN. This European standard is not intended to cover: a) loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source; b) supervisory sounders, for example, within the control and indicating equipment.

Standards Relationship
ONORM EN 54-3 : 2014 Identical
NBN EN 54-3 : 2014 Identical
NEN EN 54-3 : 2014+A1:2019 Identical
I.S. EN 54-3:2014 Identical
EN 54-3:2014 Identical
NF EN 54-3 : 2014 Identical
DIN EN 54-3:2014-09 Identical
NS EN 54-3 : 2014 Identical
UNE-EN 54-3:2016 Identical
DIN EN 54-3:2001-10 Identical

⚠

A newer version of this standard is available.

€356.52
Excluding VAT