Foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Artificial networks for AC mains and other
  power ports
5 Current and voltage probes
6 Coupling units for conducted current immunity
  measurement
7 Coupling devices for measuring signal lines
8 The artificial hand and series RC element
9 CDNE for measurement of disturbance voltage
  in frequency range 30 MHz to 300 MHz
Annex A (normative) - Characteristics and their
        measurement, circuit schemes and examples
        of modern implementations of AMNs and
        other ANs for use with power or load ports of EUTs
Annex B (informative) - Construction, frequency range, and
        calibration of current probes
Annex C (informative) - Construction of the coupling units
        for current injection for the frequency range 0,15
        MHz to 30 MHz
Annex D (informative) - Principle of operation and examples
        of coupling units for conducted current immunity
        measurements
Annex E (normative) - Example and measurement of the
        parameters of the asymmetric artificial network (AAN)
Annex F (normative) - Example and measurement of the
        parameters of the AN for coaxial and other
        screened cables
Annex G (informative) - Construction and evaluation of
        capacitive voltage probe
Annex H (informative) - Rationale for the introduction of
        a minimum decoupling factor between mains and
        EUT/receiver ports for the V-AMN
Annex I (informative) - Rationale for the introduction of a
        phase tolerance for the V-AMN input impedance
Annex J (informative) - Example CDNE set-up diagrams
Annex K (normative) - Measurement of Delta-AN parameters
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Defines the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz.

Committee
GEL/210/11
DevelopmentNote
Together with BS EN 55016-1-1, BS EN 55016-1-3, BS EN 55016-1-4 and BS EN 55016-1-5 it supersedes BS CISPR 16-1(1999). (01/2005) Supersedes 00/248013 DC. (05/2006) Supersedes 02/208871 DC. (09/2007) Supersedes 10/30234095 DC. (08/2014) 2014 Edition Re-Issued in March 2018 & incorporates AMD 1 2018. Supersedes 15/30330242 DC. (04/2018)
DocumentType
Standard
Pages
108
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

CISPR 16-1-2:2014 is available as CISPR 16-1-2:2014 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

CISPR 16-1-2:2014 specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz. It has the status of a basic EMC publication. Specifications for ancillary apparatus are included for artificial mains networks, current and voltage probes and coupling units for current injection on cables. It is intended that the requirements of this publication are fulfilled at all frequencies and for all levels of radio disturbance voltages and currents within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in the CISPR 16-2 series, and further information on radio disturbance is given in CISPR 16-3, while uncertainties, statistics and limit modelling are covered in the CISPR 16-4 series. This second edition cancels and replaces the first edition published in 2003 and its Amendment 1 (2004) and Amendment 2 (2006). This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- requirements from CISPR 22 for the AAN have been copied to this standard;
- and the CDNE for measurement of disturbance voltage in the frequency range 30 MHz to 300 MHz is added. Keywords: electromagnetic compatibility,coupling, asymetric artificial network, coupling decoupling network equipment

CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.